SD4 - Andor Revolution WD Borealis Mosaic
(change the iQ version to the current one) |
|||
Line 40: | Line 40: | ||
reflectors in IX83 stand:<br> | reflectors in IX83 stand:<br> | ||
DAPI set (Ex 377/50, DM 409, Em 447/60); GFP set (Ex 472/30, DM 495, Em 520/35); RFP set (Ex 562/40, DM 593, Em 624/40); CY5 set (Ex 628/40, DM 660, Em 692/40); Analyzer; DM for use with Mosaic | DAPI set (Ex 377/50, DM 409, Em 447/60); GFP set (Ex 472/30, DM 495, Em 520/35); RFP set (Ex 562/40, DM 593, Em 624/40); CY5 set (Ex 628/40, DM 660, Em 692/40); Analyzer; DM for use with Mosaic | ||
− | |software=Andor iQ version 3. | + | |software=Andor iQ version 3.6; MetaMorph version 7.8<br> |
communication connections:<br>COM1(Port1): IX83; COM3: CSU-WD; COM4: Mosaic shutter; COM6: prior XY stage; COM7: 16 channel CooLED; <br>Device: Mosaic; Device1: Mosaic laser; DDA06/16 DAC board: Piezo, trigger box; ILE3082M-ILE3082S: ILE master, slave | communication connections:<br>COM1(Port1): IX83; COM3: CSU-WD; COM4: Mosaic shutter; COM6: prior XY stage; COM7: 16 channel CooLED; <br>Device: Mosaic; Device1: Mosaic laser; DDA06/16 DAC board: Piezo, trigger box; ILE3082M-ILE3082S: ILE master, slave | ||
|incubation=Cage incubator (T+CO2) | |incubation=Cage incubator (T+CO2) | ||
|link1=https://docs.google.com/spreadsheets/d/1UNHFIrXe5ojXuf_fcb3H5PjxFdP4PqSeP5-Yi8-7UaE/pubhtml | |link1=https://docs.google.com/spreadsheets/d/1UNHFIrXe5ojXuf_fcb3H5PjxFdP4PqSeP5-Yi8-7UaE/pubhtml | ||
}} | }} |
Latest revision as of 11:59, 8 June 2020
[edit] Directions
[edit] Booking
https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py
[edit] Details
microscope | Olympus - IX83, Inverted stand, motorized with ZDC (hardware autofocus and focus search), Prior NanoScanZ (400um travel range), Prior ProScanIII xy scanning stage | ||
objectives | |||
illumination | |||
detection | Spinning disc scan head Yokogawa CSU-W1 (4000rpm) with two pinhole discs (50um and 25um) and
simultaneous dual camera detection: Camera 1 (Master): Andor iXon 888 Ultra with fringe suppression; Camera 2 (Slave): Andor iXon 888 Ultra | ||
reflectors | CSU-W scan head: 3 main DM: Tripple (for 445nm, 515nm, 640nm laser); Quad (405nm, 488nm, 561nm, 640nm);
Penta (405nm, 488nm, 561nm, 640nm, 720nm) reflectors in IX83 stand: | ||
features | |||
software | Andor iQ version 3.6; MetaMorph version 7.8 communication connections: | ||
incubation | Cage incubator (T+CO2) | ||
links |
| ||
inv.nr. |