Property:Detection

From BioDIP
Jump to: navigation, search

This is a property of type Text.


Pages using the property "Detection"

Showing 25 pages using this property.

(previous 25) (next 25)

A

ApoTome, 2nd floor, MTZ +Axiocam MRm (1388*1040, 6,45*6,45µm) - b/w Axiocam MRc (1388*1040 pixel, 6,45*6,45µm) - color
ApoTome1 2nd floor, inv., CRTD +Axiocam MRm (1388*1040, 6,45*6,45µm) - b/w
ApoTome1 3rd floor, upr., CRTD +Axiocam MRm (1388*1040, 6,45*6,45µm) - b/w<br /> Axiocam MRc (1388*1040 pixel, 6,45*6,45µm) - color
ApoTome1, inverse, BIOTEC +Axiocam MRm (1388*1040, 6,45*6,45µm pixel) - b/w<br /> Axiocam MRc (1388*1040, 6,45*6,45µm pixel) - color
ApoTome2, inverse, CRTD +Axiocam HRc (1388*1040, 6,45*6,45µm pixel) - color <br /> Axiocam MRm (1388*1040, 6,45*6,45µm pixel) - b/w <br /> tube lens 1x and 1.6x
Axioscan slide scanner +Orca Flash 4.0 V2 , 2048x2048 (4 Mega Pixel), 6.5x6.5 um pixel size, 1" chip size

C

CL1 - Leica TCS SP2 +point scanner, 3 confocal PMTs, T-PMT, prism and sliders for spectral detection range selection, central pinhole
CZ1 - Zeiss LSM Meta +point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector
CZ2 - Zeiss LSM UV +point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector
CZ3 - Zeiss LSM 405/594 +point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector
CZ4 - Zeiss LSM DuoScan +point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector
CZ5 - Zeiss LSM 700 inverted +2 PMTs<br /> No transmission detector
CZ6 - Zeiss LSM 880 Airy inverted +32 GaAsP PMT channels <br /> 2 PMTs<br /> 1 32-channel Airy Scan detector <br /> transmission detector
CZ7 - Zeiss LSM 880 Airy upright +32 GaAsP PMT channels <br /> 2 PMTs<br /> 1 32-channel Airy Scan detector <br /> transmission detector

D

D1 - SPIM Demo +Zeiss CCD Axiocam camera. Max 3fps full chip. Faster with binning.
Deleted - BIO25 +-

G

Grid LSM & WF, upr., BIOTEC +dual ccd configuration: Coolsnap ES for widefield fluorescence AND <br /> Cascade II EMCCD for confocal sectioning (multi point illumination, variable pinhole size), dual channel emission beamsplitter

H

H1 - DeltaVision OMX - pDV +4x sCMOS cooled to 3oC. Simultaneous or sequential imaging.
H2 - Nikon STORM - TIRF +at left camera port: Andor iXon EM+ DU-897 BV back-illuminated EM-CCD SN #4431 with cylindrical lens; dexel size of camera chip: 16um<br />at right camera port: Andor iXon3 DU-897 BV back-illuminated EM-CCD # 6499 with 10 position filter wheel and Hamamtsu W-View image splitter; dexel size of camera chip: 16um

L

L1 - Long Term Timelapse I +Princeton Instruments monochrome CCD 1024x1024 pixels (6.7 um²)
L2 - Long Term Timelapse II +Roper Scientific CoolSNAP ES, monochromatic Sony ICX285AL chip, 1392 x 1040 pixels, 6.45 μm pixel size, 20 MHz digitization, 8 e- rms readout noise @ 20 MHz, thermoelectric cooling (5°C below ambient temperature)
L4 - Long Term Time Lapse Oates Andor +iXon DU-888E-COO#BV X-4631
L5 - Olympus ScanR+CellR +Hamamatsu Camera ORCA ER, progressive scan interline CCD, 1344 x 1024 pixels, 6.45 um pixel size, 14.75 MHz digitization, 8 e- rms readout noise, 8 fps @ full frame, 18.000 e- full well capacity, 2250:1 dynamic range, peltier cooling (-20 degrees C @ 20 degrees C ambient), 12 bit ADC, 0.1 electron/pixel/sec dark current, up to 10x analog gain, offset functions
LSI Macro Confocal, CRTD +1 spectral detector (PMT)
LSM 510, inverse, BIOTEC +point scanner, 2 confocal PMTs, 1 META detector, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector