H3 Andor STORM Spinning disc
From BioDIP
(Difference between revisions)
(removed category and facility info, needs to be put back later) |
(added facility and category so that the microscope is also visible in the equipment search) |
||
Line 1: | Line 1: | ||
{{Equipment | {{Equipment | ||
− | |system-number=MPI-H3 | + | |system-number=MPI- H3 |
|system-name=Andor STORM Spinning Disc | |system-name=Andor STORM Spinning Disc | ||
|type=Microscope | |type=Microscope | ||
− | |category= | + | |category=Real-Time Confocal |
− | |facility= | + | |facility=MPI-CBG LMF |
|building=MPI-CBG | |building=MPI-CBG | ||
|room=340 | |room=340 | ||
Line 11: | Line 11: | ||
|description=Fast, "real-time" confocal imaging with FRAPPA capability. Illumination equipment: TM-LED, Andor AMH, 405nm diode laser + 488 nm solid-state laser Coherent Sapphire + 561 nm solid-state laser + 640 nm solid-state laser. | |description=Fast, "real-time" confocal imaging with FRAPPA capability. Illumination equipment: TM-LED, Andor AMH, 405nm diode laser + 488 nm solid-state laser Coherent Sapphire + 561 nm solid-state laser + 640 nm solid-state laser. | ||
|applications=confocal imaging, photobleaching and -activation of DAPI,EGFP, mCherry, Cy5 with high temporal and spatial resolution | |applications=confocal imaging, photobleaching and -activation of DAPI,EGFP, mCherry, Cy5 with high temporal and spatial resolution | ||
+ | |image=MPI-CBG-Lmf-logo-big.png | ||
|stand-name=Nikon TiE | |stand-name=Nikon TiE | ||
|stand=Inverted | |stand=Inverted |
Revision as of 18:00, 3 February 2016
Directions
Booking
https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py
Details
microscope | Nikon TiE, Inverted stand, motorized with PFS (hardware autofocus), 1.5 x Optovar, MCL Piezo 100um travel range, manual xy stage | ||
objectives | |||
illumination | |||
detection | [[detection::Spinning disc scan head Yokogawa CSU-X1 (10000rpm), manual: dichromatic mirror: Quad band T-405/488/568/647 physical pinhole radius: 25um, pinhole spacing: 250um; back-projected pinhole size: 0.4um, back-projected pinhole spacing: 4um (with 60x objective, 1x optovar) camera: Andor iXon EM+ DU-897 BV back illuminated EMCCD; dexel size of EMCCD chip: 16um ]] | ||
reflectors | Rotr filter wheel: position 0: 440/521/607/700 Quadband, 1: razor edge 488LP, 2: blocked, 3: razor edge 568LP, 4: Edge Basic longpass 635 LP, 5: BrightLine 445/45, 6: open, 7: polarizer for DIC, 8: 525/30, 9: BrightLine HC 607/36 | ||
features | FRAPPA coupled in via backport | ||
software | [[software::iQ 2.9 + iQ 3.3 (both with Python) iQ3 user guide connections: COM1 - ????; COM2xx - lasers; COM3 - ???; COM4 - ???; COM5 - ???; COM6 - ???; AOTF - ALC401/501/601; DD A06/16]] | ||
incubation | Stage incubator (T+CO2) | ||
links |
| ||
inv.nr. |