|features=simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, multi-position imaging, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation
 
|features=simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, multi-position imaging, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation
 
|incubation=-
 
|incubation=-
|link1=[http://spreadsheets.google.com/pub?key=pMZJXCgd5HNuFT702uqALWA LPM]
+
|link1=http://spreadsheets.google.com/pub?key=pMZJXCgd5HNuFT702uqALWA
 
|link2=-
 
|link2=-
 
|inv=-
 
|inv=-
 
|objectives=10x/0.4<br>20x/0.7 DIC<br>40x/0.75 DIC<br>20x/0,5 W (Dipping) DIC<br>63x/0.9 W (Dipping)<br>63x/1.2 W Corr DIC
 
|objectives=10x/0.4<br>20x/0.7 DIC<br>40x/0.75 DIC<br>20x/0,5 W (Dipping) DIC<br>63x/0.9 W (Dipping)<br>63x/1.2 W Corr DIC
 
}}
 
}}

Revision as of 14:08, 4 September 2009

Suitable for -.
Bioz02.JPG


Directions

[[image:|150px|text-bottom|right]]

[[image:|100px]] Imaging@Biotec"Imaging@Biotec" is not in the list of possible values (DZNE - Imaging Platform, EM- and Histo-Facility CRTD / BIOTEC, Image Processing@BIOTEC, Imaging@BIOTEC/CRTD, MPI-CBG LMF, MPI-CBG LMF - Quantitative Image Analysis Unit, MPI-CBG TDS, MTZ Imaging, MPI-CBG EM, BioDIP) for this property. ("Biotec" is not in the list of possible values (BIOTEC, CRTD, DZNE, MTZ, MPI-CBG) for this property., 220)

Booking

https://techpool.biotec.tu-dresden.de/schedule/schedule.php?scheduleid=sc142df4c59eef5c

Details

microscope , Upright stand, motorized XYZ stage, Z-piezo stage, fluorescence, transmitted light with automatic DIC
objectives
Leica HC PL APO 10x 0.4
Leica HC PL APO 20x 0.7
-
-
Leica HCX APO 63x 0.9 W
Leica HCX PL APO 63x 1.2 W
-
-
illumination
detection point scanner, 5 confocal PMTs, T-PMT, AOBS for excitation/emission splitting, SP detector for detection range selection, common pinhole
reflectors DAPI (A) : EX 360/40 ; BS 400 ; EM LP 425
FITC (I3) : EX 470/40 ; BS 510 ; EM LP 515
BGR Triple DAPI GFP DsRed : EX 420/30 495/15 570/20 ; BS 455 510 590 ; EM 465/20 530/30 640/40
features simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, multi-position imaging, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation
software
incubation -