MTZ01 - Zeiss LSM 510
From BioDIP
(Difference between revisions)
m |
|||
(46 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
− | = | + | {{Equipment |
− | MTZ | + | |system-number=MTZ01 |
− | + | |system-name=Zeiss LSM 510 | |
− | + | |type=Microscope | |
− | |- | + | |category=Laser Scanning Confocal |
− | | | + | |facility=MTZ Imaging |
− | | | + | |building=MTZ |
− | | | + | |room=B20.001B |
− | + | |Facility-logo=Logo mtz 3.png | |
− | + | |Institute-logo=Logo Medizin.png | |
− | + | |description=This [[Zeiss LSM 510]] [[confocal]] microscope is designed for routine work. The laser lines are well distributed over the spectrum. Due to the conventional setup, it offers straight forward working conditions. | |
− | + | |applications=routine work with fixed samples, high resolution imaging in XYZ and common dye combinations | |
− | + | |image=MTZ01.jpg | |
− | + | |stand-name=Zeiss - Axiovert 200M | |
− | + | |stand=Inverted | |
− | + | |microscope=motorized XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | |
− | + | |obj1=Zeiss EC Plan-Neofluar 10x 0.3 | |
− | | | + | |obj2=Zeiss LCI Plan-Neofluar 25x 0.8 Imm Corr |
− | | point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector | + | |obj3=Zeiss EC Plan-Neofluar 40x 1.3 Oil |
− | | simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing | + | |obj4=Zeiss Plan-Apochromat 63x 1.4 Oil |
− | |} | + | |obj5=Zeiss C-Apochromat 63x 1.2 W |
+ | |ill1=Transmitted Light (Halogen) | ||
+ | |ill2=Fluorescence (HBO) | ||
+ | |ill3=Laser Diode 405 nm | ||
+ | |ill4=Laser Argon Multiline 458, 477, 488, 514 nm | ||
+ | |ill5=Laser DPSS 561 nm | ||
+ | |ill6=Laser HeNe 633 nm | ||
+ | |detection=point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector | ||
+ | |reflectors=EX 350/50, EM 460/50<br>EX 472/30, EM 520/35<br>EX 546/12, EM LP590 | ||
+ | |features=simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation | ||
+ | |incubation=Not available | ||
+ | |link1=http://spreadsheets.google.com/pub?key=pFf3a5iBejjAwSkUV9oO6fw | ||
+ | |link2=https://spreadsheets.google.com/pub?key=pMZJXCgd5HNumbQenUfeIeA | ||
+ | |inv=- | ||
+ | |facility_image=Logo-mtzimaging.jpg | ||
+ | |objectives=10x/0.3<br>25x/0.8 ImmCorr<br>40x/1.3 Oil<br>63x/1.4 Oil Apo<br>63x/1.2 W Apo | ||
+ | |illumination=Halogen<br>HBO<br>405 nm Diode laser<br>458, 488, 514 nm Argon laser<br>561 nm DPSS laser<br>633 nm HeNe laser | ||
+ | }} |
Latest revision as of 11:40, 14 November 2013
[edit] Directions
[edit] Booking
https://cgc.med.tu-dresden.de/phpScheduleIt
[edit] Details
microscope | Zeiss - Axiovert 200M, Inverted stand, motorized XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | ||
objectives | |||
illumination | |||
detection | point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector | ||
reflectors | EX 350/50, EM 460/50 EX 472/30, EM 520/35 EX 546/12, EM LP590 | ||
features | simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation | ||
software | |||
incubation | Not available | ||
links |
| ||
inv.nr. | - |