Gallery
From BioDIP
(Difference between revisions)
(more Airy unit links) |
|||
Line 8: | Line 8: | ||
<gallery perrow=4> | <gallery perrow=4> | ||
− | Image:Confocaldualcolor_8.jpg|8 Airy | + | Image:Confocaldualcolor_8.jpg|8 [[Airy unit]]s |
− | Image:Confocaldualcolor_7.jpg|7 Airy | + | Image:Confocaldualcolor_7.jpg|7 [[Airy unit]]s |
− | Image:Confocaldualcolor_6.jpg|6 Airy | + | Image:Confocaldualcolor_6.jpg|6 [[Airy unit]]s |
− | Image:Confocaldualcolor_5.jpg|5 Airy | + | Image:Confocaldualcolor_5.jpg|5 [[Airy unit]]s |
− | Image:Confocaldualcolor_4.jpg|4 Airy | + | Image:Confocaldualcolor_4.jpg|4 [[Airy unit]]s |
− | Image:Confocaldualcolor_3.jpg|3 Airy | + | Image:Confocaldualcolor_3.jpg|3 [[Airy unit]]s |
− | Image:Confocaldualcolor_2.jpg|2 Airy | + | Image:Confocaldualcolor_2.jpg|2 [[Airy unit]]s |
− | Image:Confocaldualcolor_1.jpg|1 Airy | + | Image:Confocaldualcolor_1.jpg|1 [[Airy unit]] |
</gallery> | </gallery> | ||
Line 24: | Line 24: | ||
==== XY ==== | ==== XY ==== | ||
− | * High resolution image, acquired with decreasing pinhole diameter from 8 | + | * High resolution image, acquired with decreasing pinhole diameter from 8 [[Airy unit]]s to 0.6 [[Airy unit]]s. |
<gallery> | <gallery> | ||
− | Image:63xinvitrogen-4-PH8.jpg|8 Airy | + | Image:63xinvitrogen-4-PH8.jpg|8 [[Airy unit]]s |
− | Image:63xinvitrogen-4-PH7.jpg|7 Airy | + | Image:63xinvitrogen-4-PH7.jpg|7 [[Airy unit]]s |
− | Image:63xinvitrogen-4-PH6.jpg|6 Airy | + | Image:63xinvitrogen-4-PH6.jpg|6 [[Airy unit]]s |
− | Image:63xinvitrogen-4-PH5.jpg|5 Airy | + | Image:63xinvitrogen-4-PH5.jpg|5 [[Airy unit]]s |
− | Image:63xinvitrogen-4-PH4.jpg|4 Airy | + | Image:63xinvitrogen-4-PH4.jpg|4 [[Airy unit]]s |
− | Image:63xinvitrogen-4-PH3.jpg|3 Airy | + | Image:63xinvitrogen-4-PH3.jpg|3 [[Airy unit]]s |
− | Image:63xinvitrogen-4-PH2.jpg|2 Airy | + | Image:63xinvitrogen-4-PH2.jpg|2 [[Airy unit]]s |
− | Image:63xinvitrogen-4-PH1.jpg|1 Airy | + | Image:63xinvitrogen-4-PH1.jpg|1 [[Airy unit]] |
− | Image:63xinvitrogen-4-PH0.8.jpg|0.8 Airy | + | Image:63xinvitrogen-4-PH0.8.jpg|0.8 [[Airy unit]]s |
− | Image:63xinvitrogen-4-PH0.6.jpg|0.6 Airy | + | Image:63xinvitrogen-4-PH0.6.jpg|0.6 [[Airy unit]]s |
</gallery> | </gallery> | ||
Line 48: | Line 48: | ||
<gallery perrow=4> | <gallery perrow=4> | ||
− | Image:Pinholeseries_8.jpg|8 Airy | + | Image:Pinholeseries_8.jpg|8 [[Airy unit]]s |
− | Image:Pinholeseries_7.jpg|7 Airy | + | Image:Pinholeseries_7.jpg|7 [[Airy unit]]s |
− | Image:Pinholeseries_6.jpg|6 Airy | + | Image:Pinholeseries_6.jpg|6 [[Airy unit]]s |
− | Image:Pinholeseries_5.jpg|5 Airy | + | Image:Pinholeseries_5.jpg|5 [[Airy unit]]s |
− | Image:Pinholeseries_4.jpg|4 Airy | + | Image:Pinholeseries_4.jpg|4 [[Airy unit]]s |
− | Image:Pinholeseries_3.jpg|3 Airy | + | Image:Pinholeseries_3.jpg|3 [[Airy unit]]s |
− | Image:Pinholeseries_2.jpg|2 Airy | + | Image:Pinholeseries_2.jpg|2 [[Airy unit]]s |
− | Image:Pinholeseries_1.jpg|1 Airy | + | Image:Pinholeseries_1.jpg|1 [[Airy unit]] |
</gallery> | </gallery> | ||
Latest revision as of 22:38, 13 March 2011
Contents |
[edit] Images acquired with our equipment
[edit] Effect of the CLSM pinhole
[edit] overview images
- Typical overview image of a tissue sample region. Pinhole diameter decreases from 8 Airy units to 1 Airy unit.
- Invitrogen FluoCells(r) #4, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 488 nm + 594 nm excitation, 505-580 nm + LP610 nm detection
[edit] XY
- High resolution image, acquired with decreasing pinhole diameter from 8 Airy units to 0.6 Airy units.
0.8 Airy units
0.6 Airy units
- Invitrogen FluoCells(r) #4, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 594 nm excitation, LP610 nm detection
[edit] XYZ
- One region of the sample was imaged with decreasing pinhole diameter, starting from 8 airy units (first image) down to 1 airy units (last image).
- Invitrogen FluoCells(r) #4, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 488 nm excitation, 505-580 nm detection, 0.2 µm Z-stepsize, Bitplane Imaris
[edit] Cleaning an objective makes sense
- Invitrogen FluoCells(r) #6, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 488nm excitation, 505-550nm detection, pinhole @98µm