Zeiss ApoTome - DZNE W1
From BioDIP
(Difference between revisions)
Line 11: | Line 11: | ||
|applications=- | |applications=- | ||
|image=ApoTome1 3rd floor, upr., CRTD.jpg | |image=ApoTome1 3rd floor, upr., CRTD.jpg | ||
− | |stand-name=Zeiss - Axio Imager | + | |stand-name=Zeiss - Axio Imager.M2 |
|stand=Upright | |stand=Upright | ||
− | |microscope= | + | |microscope=manual XY stage, motorized z-drive, fluorescence, transmitted light with DIC, Ph, Darkfield b/w epifluorescence acquisition, Optical Sectioning (ApoTome2) |
− | |obj1=Zeiss Plan | + | |obj1=Zeiss EC Plan Neofluar 2.5x 0.075 |
− | |obj2=Zeiss Plan-Apochromat | + | |obj2=Zeiss Plan-Apochromat 10x 0.45 |
− | |obj3=Zeiss Plan-Apochromat | + | |obj3=Zeiss Plan-Apochromat 20x 0.8 |
|obj4=Zeiss Plan-Apochromat 40x 0,95 korr. | |obj4=Zeiss Plan-Apochromat 40x 0,95 korr. | ||
− | |obj5 | + | |obj5=Zeiss EC Plan-Neofluar 100x 1.3 Oil |
− | + | ||
− | + | ||
|ill1=Fluorescence (Metal Halide, HXP, 120W) | |ill1=Fluorescence (Metal Halide, HXP, 120W) | ||
|ill2=Transmitted Light (Halogen) | |ill2=Transmitted Light (Halogen) | ||
− | |detection=Axiocam MRm (1388*1040, 6,45*6,45µm) | + | |detection=Axiocam MRm rev.3 (1388*1040, 6,45*6,45µm) |
− | + | ||
|reflectors=FS 49: EX BP G365; BS 395; EM BP 445/50 (Dapi)<br> | |reflectors=FS 49: EX BP G365; BS 395; EM BP 445/50 (Dapi)<br> | ||
FS HC-FITC: EX BP 482/35 (HE); BS 505 (HE); EM BP 536/40 (HE); (GFP)<br> | FS HC-FITC: EX BP 482/35 (HE); BS 505 (HE); EM BP 536/40 (HE); (GFP)<br> | ||
− | |||
FS Cy5 HC: EX BP 640/30 ; BS 660 ; EM 690/50; (Cy5)<br> | FS Cy5 HC: EX BP 640/30 ; BS 660 ; EM 690/50; (Cy5)<br> | ||
− | + | ||
FS Analysator for DIC and Transmission | FS Analysator for DIC and Transmission | ||
− | |features=sequential imaging, Brightfield and Fluorescence overlay, timelapse, z-stack, optical sectioning | + | |features=sequential imaging, Brightfield and Fluorescence overlay, timelapse, z-stack, optical sectioning |
− | |software= | + | |software=AxioVision Rel.4.8.2 |
|incubation=Not available | |incubation=Not available | ||
|inv=0 | |inv=0 | ||
}} | }} |
Revision as of 15:19, 12 March 2012
Directions
Booking
https://techpool.biotec.tu-dresden.de/schedule/schedule.php?scheduleid=sc14ffd3aa3e44c3
Details
microscope | Zeiss - Axio Imager.M2, Upright stand, manual XY stage, motorized z-drive, fluorescence, transmitted light with DIC, Ph, Darkfield b/w epifluorescence acquisition, Optical Sectioning (ApoTome2) | ||
objectives | |||
illumination | |||
detection | Axiocam MRm rev.3 (1388*1040, 6,45*6,45µm) | ||
reflectors | FS 49: EX BP G365; BS 395; EM BP 445/50 (Dapi) FS HC-FITC: EX BP 482/35 (HE); BS 505 (HE); EM BP 536/40 (HE); (GFP) FS Analysator for DIC and Transmission | ||
features | sequential imaging, Brightfield and Fluorescence overlay, timelapse, z-stack, optical sectioning | ||
software | AxioVision Rel.4.8.2 | ||
incubation | Not available | ||
links |
| ||
inv.nr. | 0 |