ApoTome1, inverse, BIOTEC
From BioDIP
(Difference between revisions)
Line 23: | Line 23: | ||
|ill1=Fluorescence (Metal Halide, HXP, 120W) | |ill1=Fluorescence (Metal Halide, HXP, 120W) | ||
|ill2=Transmitted Light (Halogen) | |ill2=Transmitted Light (Halogen) | ||
− | |detection=Axiocam HR (1300*1030, 6,7*6,7µm pixel)<br> | + | |detection=Axiocam HR (1300*1030, 6,7*6,7µm pixel) - b/w<br>Axiocam MRc (1388*1040, 6,45*6,45µm pixel) - color |
|reflectors=DAPI : EX 360/40 ; BS 400 ; EM 460/50<br>GFP : EX 470/40 ; BS 495 ; EM 525/50<br>Cy3 : EX 545/25 ; BS 565 ; EM 605/70<br>Cy5 : EX 620/60 ; BS 660 ; EM 700/75 | |reflectors=DAPI : EX 360/40 ; BS 400 ; EM 460/50<br>GFP : EX 470/40 ; BS 495 ; EM 525/50<br>Cy3 : EX 545/25 ; BS 565 ; EM 605/70<br>Cy5 : EX 620/60 ; BS 660 ; EM 700/75 | ||
|features=sequential imaging, Brightfield and Fluorescence overlay, timelapse, z-stack, optical sectioning, micromanipulator | |features=sequential imaging, Brightfield and Fluorescence overlay, timelapse, z-stack, optical sectioning, micromanipulator |
Revision as of 10:40, 13 December 2010
Directions
Booking
https://techpool.biotec.tu-dresden.de/schedule/schedule.php?scheduleid=sc142df4c59eef5c
Details
microscope | Zeiss - Axio Observer, Inverted stand, manual XY stage, motorized z-stage, fluorescence, transmitted light with manual DIC (Senarmont), b/w epifluorescence acquisition, Optical Sectioning (Apotome) | ||
objectives | |||
illumination | |||
detection | Axiocam HR (1300*1030, 6,7*6,7µm pixel) - b/w Axiocam MRc (1388*1040, 6,45*6,45µm pixel) - color | ||
reflectors | DAPI : EX 360/40 ; BS 400 ; EM 460/50 GFP : EX 470/40 ; BS 495 ; EM 525/50 Cy3 : EX 545/25 ; BS 565 ; EM 605/70 Cy5 : EX 620/60 ; BS 660 ; EM 700/75 | ||
features | sequential imaging, Brightfield and Fluorescence overlay, timelapse, z-stack, optical sectioning, micromanipulator | ||
software | - | ||
incubation | Not available | ||
links |
| ||
inv.nr. | 0 |