ApoTome1, inverse, BIOTEC

From BioDIP
(Difference between revisions)
Jump to: navigation, search
Line 13: Line 13:
 
|stand=Inverted
 
|stand=Inverted
 
|microscope=manual XY stage, motorized z-stage, fluorescence, transmitted light with manual DIC (Senarmont), b/w epifluorescence acquisition, Optical Sectioning (Apotome)
 
|microscope=manual XY stage, motorized z-stage, fluorescence, transmitted light with manual DIC (Senarmont), b/w epifluorescence acquisition, Optical Sectioning (Apotome)
|obj1=Zeiss EC Plan-Neofluar 10x 0.3 Ph1
+
|obj1=-
|obj2=-
+
|obj2=Zeiss LD Achroplan 20x 0.4 Ph2
|obj3=Zeiss LD Achroplan 20x 0.4 Ph2
+
|obj3=Zeiss LD Achroplan 40x 0.6 Ph2
 
|obj4=Zeiss EC Plan-Neofluar 40x 1.3 Oil
 
|obj4=Zeiss EC Plan-Neofluar 40x 1.3 Oil
 
|obj5=Zeiss Plan-Apochromat 63x 1.4 Oil
 
|obj5=Zeiss Plan-Apochromat 63x 1.4 Oil
|obj6=-
+
|obj6=Zeiss alpha Plan-Fluar 100x 1.45 Oil
 
|obj7=-
 
|obj7=-
 
|obj8=-
 
|obj8=-
|illumination=X-Cite Series 120<br>Halogen
+
|ill1=Fluorescence (HBO)
 +
|ill2=Transmitted Light (Halogen)
 +
|ill3=-
 +
|ill4=-
 +
|ill5=-
 +
|ill6=-
 +
|ill7=-
 +
|ill8=-
 
|detection=Axiocam HR (1300*1030, 6,7*6,7µm pixel)<br>Apotome
 
|detection=Axiocam HR (1300*1030, 6,7*6,7µm pixel)<br>Apotome
|reflectors=DAPI : EX 360/40 ; BS 400 ; EM 460/50<br>GFP : EX 470/40 ; BS 495 ; EM 525/50<br>Cy3 : EX 545/25 ; BS 565 ; EM 605/70<br>Cy5 : EX 620/60 ; BS 660 ; EM 700/75
+
|reflectors=DAPI : EX 360/40 ; BS 400 ; EM 460/50<br>GFP : EX 470/40 ; BS 495 ; EM 525/50<br>Cy3 : EX 545/25 ; BS 565 ; EM 605/70<br>Cy5 : EX 620/60 ; BS 660 ; EM 700/75<br>empty
 
|features=sequential imaging, Brightfield and Fluorescence overlay, timelapse, z-stack, optical sectioning, micromanipulator
 
|features=sequential imaging, Brightfield and Fluorescence overlay, timelapse, z-stack, optical sectioning, micromanipulator
 
|incubation=-
 
|incubation=-
Line 30: Line 37:
 
|inv=0
 
|inv=0
 
|objectives=10x/0.3 Ph1<br>10x/0.45 W<br>20x/0.4 Ph2 Corr LD<br>40x/1.3 Oil DIC<br>63x/1.4 Oil DIC
 
|objectives=10x/0.3 Ph1<br>10x/0.45 W<br>20x/0.4 Ph2 Corr LD<br>40x/1.3 Oil DIC<br>63x/1.4 Oil DIC
 +
|illumination=X-Cite Series 120<br>Halogen
 
}}
 
}}

Revision as of 15:58, 7 September 2009

Suitable for -.
Bioz13.jpg


Directions

[[image:|150px|text-bottom|right]]

[[image:|100px]] Imaging@Biotec"Imaging@Biotec" is not in the list of possible values (DZNE - Imaging Platform, EM- and Histo-Facility CRTD / BIOTEC, Image Processing@BIOTEC, Imaging@BIOTEC/CRTD, MPI-CBG LMF, MPI-CBG LMF - Quantitative Image Analysis Unit, MPI-CBG TDS, MTZ Imaging, MPI-CBG EM, BioDIP) for this property. ("Biotec" is not in the list of possible values (BIOTEC, CRTD, DZNE, MTZ, MPI-CBG) for this property., 225)

Booking

https://techpool.biotec.tu-dresden.de/schedule/schedule.php?scheduleid=sc142df4c59eef5c

Details

microscope , Inverted stand, manual XY stage, motorized z-stage, fluorescence, transmitted light with manual DIC (Senarmont), b/w epifluorescence acquisition, Optical Sectioning (Apotome)
objectives
-
Zeiss LD Achroplan 20x 0.4 Ph2
Zeiss LD Achroplan 40x 0.6 Ph2
Zeiss EC Plan-Neofluar 40x 1.3 Oil
Zeiss Plan-Apochromat 63x 1.4 Oil
Zeiss alpha Plan-Fluar 100x 1.45 Oil
-
-
illumination
Fluorescence (HBO)
Transmitted Light (Halogen)
-
-
-
-
-
-
detection Axiocam HR (1300*1030, 6,7*6,7µm pixel)
Apotome
reflectors DAPI : EX 360/40 ; BS 400 ; EM 460/50
GFP : EX 470/40 ; BS 495 ; EM 525/50
Cy3 : EX 545/25 ; BS 565 ; EM 605/70
Cy5 : EX 620/60 ; BS 660 ; EM 700/75
empty
features sequential imaging, Brightfield and Fluorescence overlay, timelapse, z-stack, optical sectioning, micromanipulator
software
incubation -
links
  • [ manual]
  • [- laser power values]
  • [- beam path]
  • [ advanced system check]
inv.nr. 0



Personal tools