CL1 - Leica TCS SP2
From BioDIP
(Difference between revisions)
(22 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{Equipment | {{Equipment | ||
− | |system-number= | + | |system-number=MPI-CL1 |
|system-name=Leica TCS SP2 | |system-name=Leica TCS SP2 | ||
− | |type= | + | |type=Not listed |
|category=Laser Scanning Confocal | |category=Laser Scanning Confocal | ||
|facility=MPI-CBG LMF | |facility=MPI-CBG LMF | ||
|building=MPI-CBG | |building=MPI-CBG | ||
− | |room= | + | |room=315 |
− | | | + | |Facility-logo=MPI-CBG-Lmf-logo-big.png |
− | |description=[[Leica TCS SP2]] single photon [[confocal]] scanning system with three confocal PMTs and transmitted light detector. | + | |Institute-logo=Logo MPI-CBG.jpg |
+ | |description=[[Leica TCS SP2]] single photon [[confocal]] scanning system with three confocal PMTs and transmitted light detector. For best performance, consider the [[Leica TCS SP2 - Beam Expander|recommended 'beam expander' settings]]. | ||
|applications=experiments and samples that require dipping lenses | |applications=experiments and samples that require dipping lenses | ||
− | |image= | + | |image=CL1 - Leica TCS SP2.jpg |
− | |stand= | + | |stand-name=Leica - DMRE |
+ | |stand=Upright | ||
|microscope=manual XY stage, motorized Z-drive, fast Z-stage, fluorescence, transmitted light with manual DIC | |microscope=manual XY stage, motorized Z-drive, fast Z-stage, fluorescence, transmitted light with manual DIC | ||
− | | | + | |obj1=Leica HC PlanFluotar 10x 0.3 |
− | | | + | |obj2=Leica HC PlanApochromat 20x 0.7 Oil/Glyc/Water |
− | |detection=point scanner, 3 confocal PMTs, T-PMT, prism and | + | |obj3=Leica HCX PlanApochromat 40x 1.25 Oil |
+ | |obj4=Leica HCX PlanApochromat 63x 1.32 Oil | ||
+ | |obj5=Leica HCX PlanApochromat 100x 1.40 Oil | ||
+ | |obj6=Leica HCX Apochromat 40x 0.8 W | ||
+ | |obj7=Leica HCX Apochromat 63x 0.9 W | ||
+ | |ill1=Transmitted Light (Halogen) | ||
+ | |ill2=Fluorescence (HBO) | ||
+ | |ill3=Laser Argon Multiline 458, 477, 488, 496, 514 nm | ||
+ | |ill4=Laser HeNe 543 nm | ||
+ | |ill5=Laser HeNe 633 nm | ||
+ | |detection=point scanner, 3 confocal PMTs, T-PMT, prism and sliders for spectral detection range selection, central pinhole | ||
|reflectors=EX 450-490, EM LP515<br>EX 515-560, EM LP590 | |reflectors=EX 450-490, EM LP515<br>EX 515-560, EM LP590 | ||
|features=imaging up to 4096x4096, simultaneous imaging up to 3 channels, sequential imaging, spectral imaging, line scan, point scan, Z stacks, time-series, averaging, summarizing, scan zoom and rotation | |features=imaging up to 4096x4096, simultaneous imaging up to 3 channels, sequential imaging, spectral imaging, line scan, point scan, Z stacks, time-series, averaging, summarizing, scan zoom and rotation | ||
− | |incubation= | + | |software=LCS |
− | |link1= | + | |incubation=Not available |
− | |link2= | + | |link1=http://spreadsheets.google.com/pub?key=pFACvabR4mSk3MrdrZfd6dA |
− | |inv=402527 | + | |link2=http://spreadsheets.google.com/pub?key=pMZJXCgd5HNuwNRzSWpooJw |
− | | | + | |inv=402527 10.1.40.195 |
− | | | + | |facility_image=logo-lmf.jpg |
− | + | |objectives=10x/0.3 Fluotar<br>20x/0.7 Imm corr CS Apo<br>40x/1.25-0.75 Oil CS Apo<br>63x/1.32-0.6 Oil CS Apo<br>63x/0.9 W Dipping Apo | |
− | + | |illumination=Halogen<br>HBO<br>458, 476, 488, 514 nm Argon laser<br>543 nm HeNe laser<br>633 nm HeNe laser | |
− | | | + | |
− | + | ||
− | + | ||
− | + | ||
}} | }} |
Latest revision as of 15:39, 3 February 2016
[edit] Directions
[edit] Booking
https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py
[edit] Details
microscope | Leica - DMRE, Upright stand, manual XY stage, motorized Z-drive, fast Z-stage, fluorescence, transmitted light with manual DIC | ||
objectives | |||
illumination | |||
detection | point scanner, 3 confocal PMTs, T-PMT, prism and sliders for spectral detection range selection, central pinhole | ||
reflectors | EX 450-490, EM LP515 EX 515-560, EM LP590 | ||
features | imaging up to 4096x4096, simultaneous imaging up to 3 channels, sequential imaging, spectral imaging, line scan, point scan, Z stacks, time-series, averaging, summarizing, scan zoom and rotation | ||
software | LCS | ||
incubation | Not available | ||
links |
| ||
inv.nr. | 402527 10.1.40.195 |