CL1 - Leica TCS SP2

From BioDIP
(Difference between revisions)
Jump to: navigation, search
 
(14 intermediate revisions by 3 users not shown)
Line 1: Line 1:
 
{{Equipment
 
{{Equipment
|system-number=MPI03
+
|system-number=MPI-CL1
 
|system-name=Leica TCS SP2
 
|system-name=Leica TCS SP2
|type=Microscope
+
|type=Not listed
 
|category=Laser Scanning Confocal
 
|category=Laser Scanning Confocal
 
|facility=MPI-CBG LMF
 
|facility=MPI-CBG LMF
 
|building=MPI-CBG
 
|building=MPI-CBG
|room=038B
+
|room=315
|facility_image=logo-lmf.jpg
+
|Facility-logo=MPI-CBG-Lmf-logo-big.png
 +
|Institute-logo=Logo MPI-CBG.jpg
 
|description=[[Leica TCS SP2]] single photon [[confocal]] scanning system with three confocal PMTs and transmitted light detector. For best performance, consider the [[Leica TCS SP2 - Beam Expander|recommended 'beam expander' settings]].
 
|description=[[Leica TCS SP2]] single photon [[confocal]] scanning system with three confocal PMTs and transmitted light detector. For best performance, consider the [[Leica TCS SP2 - Beam Expander|recommended 'beam expander' settings]].
 
|applications=experiments and samples that require dipping lenses
 
|applications=experiments and samples that require dipping lenses
|image=MPI03.jpg
+
|image=CL1 - Leica TCS SP2.jpg
 +
|stand-name=Leica - DMRE
 
|stand=Upright
 
|stand=Upright
 
|microscope=manual XY stage, motorized Z-drive, fast Z-stage, fluorescence, transmitted light with manual DIC
 
|microscope=manual XY stage, motorized Z-drive, fast Z-stage, fluorescence, transmitted light with manual DIC
|obj1=Leica HC PL FLUOTAR 10x 0.3
+
|obj1=Leica HC PlanFluotar 10x 0.3
|obj2=Leica HC PL APO 20x 0.7 Imm Corr
+
|obj2=Leica HC PlanApochromat 20x 0.7 Oil/Glyc/Water
|obj3=Leica HCX PL APO 40x 1.25-0.75 Oil
+
|obj3=Leica HCX PlanApochromat 40x 1.25 Oil
|obj4=Leica HCX PL APO 63x 1.32-0.6 Oil
+
|obj4=Leica HCX PlanApochromat 63x 1.32 Oil
|obj5=Leica HCX APO 63x 0.9 W
+
|obj5=Leica HCX PlanApochromat 100x 1.40 Oil
|obj6=-
+
|obj6=Leica HCX Apochromat 40x 0.8 W
|obj7=-
+
|obj7=Leica HCX Apochromat 63x 0.9 W
|obj8=-
+
 
|ill1=Transmitted Light (Halogen)
 
|ill1=Transmitted Light (Halogen)
 
|ill2=Fluorescence (HBO)
 
|ill2=Fluorescence (HBO)
Line 26: Line 27:
 
|ill4=Laser HeNe 543 nm
 
|ill4=Laser HeNe 543 nm
 
|ill5=Laser HeNe 633 nm
 
|ill5=Laser HeNe 633 nm
|ill6=-
+
|detection=point scanner, 3 confocal PMTs, T-PMT, prism and sliders for spectral detection range selection, central pinhole
|ill7=-
+
|ill8=-
+
|detection=point scanner, 3 confocal PMTs, T-PMT, prism and spectral sliders for detection range selection, central pinhole
+
 
|reflectors=EX 450-490, EM LP515<br>EX 515-560, EM LP590
 
|reflectors=EX 450-490, EM LP515<br>EX 515-560, EM LP590
 
|features=imaging up to 4096x4096, simultaneous imaging up to 3 channels, sequential imaging, spectral imaging, line scan, point scan, Z stacks, time-series, averaging, summarizing, scan zoom and rotation
 
|features=imaging up to 4096x4096, simultaneous imaging up to 3 channels, sequential imaging, spectral imaging, line scan, point scan, Z stacks, time-series, averaging, summarizing, scan zoom and rotation
|incubation=-
+
|software=LCS
 +
|incubation=Not available
 
|link1=http://spreadsheets.google.com/pub?key=pFACvabR4mSk3MrdrZfd6dA
 
|link1=http://spreadsheets.google.com/pub?key=pFACvabR4mSk3MrdrZfd6dA
 
|link2=http://spreadsheets.google.com/pub?key=pMZJXCgd5HNuwNRzSWpooJw
 
|link2=http://spreadsheets.google.com/pub?key=pMZJXCgd5HNuwNRzSWpooJw
|inv=402527
+
|inv=402527   10.1.40.195
 +
|facility_image=logo-lmf.jpg
 
|objectives=10x/0.3 Fluotar<br>20x/0.7 Imm corr CS Apo<br>40x/1.25-0.75 Oil CS Apo<br>63x/1.32-0.6 Oil CS Apo<br>63x/0.9 W Dipping Apo
 
|objectives=10x/0.3 Fluotar<br>20x/0.7 Imm corr CS Apo<br>40x/1.25-0.75 Oil CS Apo<br>63x/1.32-0.6 Oil CS Apo<br>63x/0.9 W Dipping Apo
 
|illumination=Halogen<br>HBO<br>458, 476, 488, 514 nm Argon laser<br>543 nm HeNe laser<br>633 nm HeNe laser
 
|illumination=Halogen<br>HBO<br>458, 476, 488, 514 nm Argon laser<br>543 nm HeNe laser<br>633 nm HeNe laser
 
}}
 
}}

Latest revision as of 15:39, 3 February 2016

Suitable for experiments and samples that require dipping lenses.
CL1 - Leica TCS SP2.jpg


[edit] Directions

Logo MPI-CBG.jpg
MPI-CBG-Lmf-logo-big.pngMPI-CBG LMF (MPI-CBG, 315)

[edit] Booking

https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py

[edit] Details

microscope Leica - DMRE, Upright stand, manual XY stage, motorized Z-drive, fast Z-stage, fluorescence, transmitted light with manual DIC
objectives
Leica HC PlanFluotar 10x 0.3
Leica HC PlanApochromat 20x 0.7 Oil/Glyc/Water
Leica HCX PlanApochromat 40x 1.25 Oil
Leica HCX PlanApochromat 63x 1.32 Oil
Leica HCX PlanApochromat 100x 1.40 Oil
Leica HCX Apochromat 40x 0.8 W
Leica HCX Apochromat 63x 0.9 W
illumination
Transmitted Light (Halogen)
Fluorescence (HBO)
Laser Argon Multiline 458, 477, 488, 496, 514 nm
Laser HeNe 543 nm
Laser HeNe 633 nm
detection point scanner, 3 confocal PMTs, T-PMT, prism and sliders for spectral detection range selection, central pinhole
reflectors EX 450-490, EM LP515
EX 515-560, EM LP590
features imaging up to 4096x4096, simultaneous imaging up to 3 channels, sequential imaging, spectral imaging, line scan, point scan, Z stacks, time-series, averaging, summarizing, scan zoom and rotation
software LCS
incubation Not available
links
inv.nr. 402527 10.1.40.195



Personal tools