CZ2 - Zeiss LSM UV
From BioDIP
(Difference between revisions)
Line 13: | Line 13: | ||
|stand=Inverted | |stand=Inverted | ||
|microscope=manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | |microscope=manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|obj1=Zeiss Plan-Apochromat 10x 0.45 | |obj1=Zeiss Plan-Apochromat 10x 0.45 | ||
|obj2=Zeiss LCI Plan-Neofluar 25x 0.8 Imm Corr | |obj2=Zeiss LCI Plan-Neofluar 25x 0.8 Imm Corr | ||
Line 30: | Line 21: | ||
|obj7=- | |obj7=- | ||
|obj8=- | |obj8=- | ||
+ | |ill1=Transmitted Light (Halogen) | ||
+ | |ill2=Fluorescence (HBO) | ||
+ | |ill3=- | ||
+ | |ill4=Laser Argon Multiline 458, 477, 488, 514 nm | ||
+ | |ill5=Laser HeNe 543 nm | ||
+ | |ill6=Laser HeNe 633 nm | ||
+ | |ill7=- | ||
+ | |ill8=- | ||
+ | |detection=point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector | ||
+ | |reflectors=EX 359-371, EM LP397 (Zeiss FS01)<br>EX 449-498, EM LP520 (Zeiss FS09)<br>EX 540-551, EM LP590 (Zeiss FS15) | ||
+ | |features=simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, averaging, summarizing, scan zoom and rotation | ||
+ | |incubation=stage incubator (T) + objective heater | ||
+ | |link1=http://spreadsheets.google.com/pub?key=pFACvabR4mSk0c_q3sEgGIw | ||
+ | |link2=http://spreadsheets.google.com/pub?key=pMZJXCgd5HNsP92avQu4iGA | ||
+ | |inv=2002-01425 SIP: 71648 | ||
+ | |objectives=10x/0.45 Apo<br>25x/0.8 ImmCorr<br>40x/1.3 Oil<br>63x/1.4 Oil Apo<br>63x/1.2 W Apo<br>100x/1.3 Oil | ||
+ | |illumination=Halogen<br>HBO<br>351, 364 nm UV laser<br>458, 477, 488, 514 nm Argon laser<br>543 nm HeNe laser<br>633 nm HeNe laser | ||
}} | }} |
Revision as of 14:48, 4 September 2009
Directions
[[image:|150px|text-bottom|right]]
Booking
https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py
Details
microscope | , Inverted stand, manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | ||
objectives | |||
illumination | |||
detection | point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector | ||
reflectors | EX 359-371, EM LP397 (Zeiss FS01) EX 449-498, EM LP520 (Zeiss FS09) EX 540-551, EM LP590 (Zeiss FS15) | ||
features | simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, averaging, summarizing, scan zoom and rotation | ||
software | |||
incubation | stage incubator (T) + objective heater | ||
links |
| ||
inv.nr. | 2002-01425 SIP: 71648 |