CZ2 - Zeiss LSM UV

From BioDIP
(Difference between revisions)
Jump to: navigation, search
(New page: {{Equipment | system-number = 02 | system-name = Zeiss LSM UV | category = Laser Scanning Confocal | image = MPI02.jpg | facility = M...)
 
Line 8: Line 8:
 
| building            = MPI-CBG
 
| building            = MPI-CBG
 
| room                = 038A
 
| room                = 038A
| description          =  
+
| description          = Single photon point scanning system with three confocal PMTs and transmitted light detector. Inverted setup with UV laser for special stainings, i.e. with lipid dyes.
| microscope          =  
+
| microscope          = inverted stand, manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC
| objectives          =  
+
| objectives          = 10x/0.45 Apo<br>25x/0.8 ImmCorr<br>40x/1.3 Oil<br>63x/1.4 Oil Apo<br>100x/1.4 Oil Apo<br>100x/1.3 Oil
| excitation          =  
+
| excitation          = HBO<br>351, 364 nm UV laser<br>458, 477, 488, 514 nm Argon laser<br>543 nm HeNe laser<br>633 nm HeNe laser
| detection            =  
+
| detection            = point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector
| reflectors          =  
+
| reflectors          = DAPI (EX 359-371, EM LP397)<br>GFP (EX 449-498, EM LP520)<br>EX 540-551, EM LP590
| features            =  
+
| features            = simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation
 
| incubation          = mobile stage incubator
 
| incubation          = mobile stage incubator
 
}}
 
}}

Revision as of 14:05, 16 June 2008

Suitable for text.
MPI02.jpg


Directions

[[image:|150px|text-bottom|right]]

[[image:|100px]] MPI-CBG LMF (MPI-CBG, 038A)

Booking

https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py

Details

microscope , stand, inverted stand, manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC
objectives
illumination
detection point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector
reflectors DAPI (EX 359-371, EM LP397)
GFP (EX 449-498, EM LP520)
EX 540-551, EM LP590
features simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation
software
incubation mobile stage incubator
links
  • [ manual]
  • [ laser power values]
  • [ beam path]
  • [ advanced system check]
inv.nr.



[[Category:{{{type}}}]]