CZ3 - Zeiss LSM 405/594

From BioDIP
(Difference between revisions)
Jump to: navigation, search
Line 9: Line 9:
 
| building            = MPI-CBG
 
| building            = MPI-CBG
 
| room                = 038A
 
| room                = 038A
| description          = Single photon point scanning system with three confocal PMTs and transmitted light detector.  
+
| description          = Single photon point scanning [[Zeiss LSM 510]] [[confocal]] system with three PMTs and transmitted light detector.  
 
| microscope          = inverted stand, manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC
 
| microscope          = inverted stand, manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC
 
| objectives          = 10x/0.45 Plan-Neo<br>25x/0.8 Imm corr. Plan-Neo<br>40x/1.3 Oil Plan-Neo<br>40x/1.2 W corr. Apo<br>63x/1.4 Oil Plan-Apo<br>63x/1.2 W Apo
 
| objectives          = 10x/0.45 Plan-Neo<br>25x/0.8 Imm corr. Plan-Neo<br>40x/1.3 Oil Plan-Neo<br>40x/1.2 W corr. Apo<br>63x/1.4 Oil Plan-Apo<br>63x/1.2 W Apo
Line 15: Line 15:
 
| detection            = point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector
 
| detection            = point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector
 
| reflectors          = EX 323-380, EM 417-469<br>EX 422-443, EM 458-498<br>EX 451-489, EM 496-546<br>EX 531-581, EM LP617
 
| reflectors          = EX 323-380, EM 417-469<br>EX 422-443, EM 458-498<br>EX 451-489, EM 496-546<br>EX 531-581, EM LP617
| features            = simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation
+
| features            = simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, [[averaging]], summarizing, scan zoom and rotation
 
| incubation          = mobile stage incubator
 
| incubation          = mobile stage incubator
 
| link1                = [http://web-redaktion.tu-dresden.de/die_tu_dresden/fakultaeten/medizinische_fakultaet/mtz/mtzImaging/ifn/lpm/MPI04 LPM]
 
| link1                = [http://web-redaktion.tu-dresden.de/die_tu_dresden/fakultaeten/medizinische_fakultaet/mtz/mtzImaging/ifn/lpm/MPI04 LPM]
 
| link2                = [http://web-redaktion.tu-dresden.de/die_tu_dresden/fakultaeten/medizinische_fakultaet/mtz/mtzImaging/ifn/equipment-files/04_zeiss_lsm_405-594_filterconfig.pdf scan-head filter configuration]
 
| link2                = [http://web-redaktion.tu-dresden.de/die_tu_dresden/fakultaeten/medizinische_fakultaet/mtz/mtzImaging/ifn/equipment-files/04_zeiss_lsm_405-594_filterconfig.pdf scan-head filter configuration]
 
}}
 
}}

Revision as of 17:07, 27 June 2008

Suitable for text.
MPI04.jpg


Directions

[[image:|150px|text-bottom|right]]

[[image:|100px]] MPI-CBG LMF (MPI-CBG, 038A)

Booking

https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py

Details

microscope , inverted stand, inverted stand, manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC
objectives
illumination
detection point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector
reflectors EX 323-380, EM 417-469
EX 422-443, EM 458-498
EX 451-489, EM 496-546
EX 531-581, EM LP617
features [[features::simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation]]
software
incubation mobile stage incubator
links
  • [ manual]
  • [LPM laser power values]
inv.nr.



[[Category:{{{type}}}]]