CZ3 - Zeiss LSM 405/594
From BioDIP
(Difference between revisions)
Line 9: | Line 9: | ||
| building = MPI-CBG | | building = MPI-CBG | ||
| room = 038A | | room = 038A | ||
− | | description = Single photon point scanning system with three | + | | description = Single photon point scanning [[Zeiss LSM 510]] [[confocal]] system with three PMTs and transmitted light detector. |
| microscope = inverted stand, manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | | microscope = inverted stand, manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | ||
| objectives = 10x/0.45 Plan-Neo<br>25x/0.8 Imm corr. Plan-Neo<br>40x/1.3 Oil Plan-Neo<br>40x/1.2 W corr. Apo<br>63x/1.4 Oil Plan-Apo<br>63x/1.2 W Apo | | objectives = 10x/0.45 Plan-Neo<br>25x/0.8 Imm corr. Plan-Neo<br>40x/1.3 Oil Plan-Neo<br>40x/1.2 W corr. Apo<br>63x/1.4 Oil Plan-Apo<br>63x/1.2 W Apo | ||
Line 15: | Line 15: | ||
| detection = point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector | | detection = point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector | ||
| reflectors = EX 323-380, EM 417-469<br>EX 422-443, EM 458-498<br>EX 451-489, EM 496-546<br>EX 531-581, EM LP617 | | reflectors = EX 323-380, EM 417-469<br>EX 422-443, EM 458-498<br>EX 451-489, EM 496-546<br>EX 531-581, EM LP617 | ||
− | | features = simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation | + | | features = simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, [[averaging]], summarizing, scan zoom and rotation |
| incubation = mobile stage incubator | | incubation = mobile stage incubator | ||
| link1 = [http://web-redaktion.tu-dresden.de/die_tu_dresden/fakultaeten/medizinische_fakultaet/mtz/mtzImaging/ifn/lpm/MPI04 LPM] | | link1 = [http://web-redaktion.tu-dresden.de/die_tu_dresden/fakultaeten/medizinische_fakultaet/mtz/mtzImaging/ifn/lpm/MPI04 LPM] | ||
| link2 = [http://web-redaktion.tu-dresden.de/die_tu_dresden/fakultaeten/medizinische_fakultaet/mtz/mtzImaging/ifn/equipment-files/04_zeiss_lsm_405-594_filterconfig.pdf scan-head filter configuration] | | link2 = [http://web-redaktion.tu-dresden.de/die_tu_dresden/fakultaeten/medizinische_fakultaet/mtz/mtzImaging/ifn/equipment-files/04_zeiss_lsm_405-594_filterconfig.pdf scan-head filter configuration] | ||
}} | }} |
Revision as of 17:07, 27 June 2008
Directions
[[image:|150px|text-bottom|right]]
Booking
https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py
Details
microscope | , inverted stand, inverted stand, manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | ||
objectives |
| ||
illumination |
| ||
detection | point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector | ||
reflectors | EX 323-380, EM 417-469 EX 422-443, EM 458-498 EX 451-489, EM 496-546 EX 531-581, EM LP617 | ||
features | [[features::simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation]] | ||
software | |||
incubation | mobile stage incubator | ||
links |
| ||
inv.nr. |
[[Category:{{{type}}}]]