CZ6 - Zeiss LSM 880 Airy inverted

From BioDIP
(Difference between revisions)
Jump to: navigation, search
(creation of page, copy whole page content from CZ7)
 
(changed all relevant information to that of CZ6 (as far as I know))
Line 9: Line 9:
 
|Facility-logo=MPI-CBG-Lmf-logo-big.png
 
|Facility-logo=MPI-CBG-Lmf-logo-big.png
 
|Institute-logo=Logo MPI-CBG.jpg
 
|Institute-logo=Logo MPI-CBG.jpg
|description=Zeiss LSM 880 upright
+
|description=Zeiss LSM 880 inverted
 
single photon point scanning confocal system with Quasar detector (32 spectral detection channels in the GaAsP detector plus 2PMTs) and transmitted light detector.  
 
single photon point scanning confocal system with Quasar detector (32 spectral detection channels in the GaAsP detector plus 2PMTs) and transmitted light detector.  
 
Airy scan detector for high resolution imaging.
 
Airy scan detector for high resolution imaging.
 
Motorized stage for multi-point acquisition
 
Motorized stage for multi-point acquisition
 
|applications=Optical sectioning for 3D reconstruction; fast bleaching samples; high-resolution imaging; multi-color imaging; linear and spectral unmixing of overlapping emission spectra; tile scan; multi position scan; FRAP; FRET
 
|applications=Optical sectioning for 3D reconstruction; fast bleaching samples; high-resolution imaging; multi-color imaging; linear and spectral unmixing of overlapping emission spectra; tile scan; multi position scan; FRAP; FRET
|image=CZ7 - Zeiss LSM 880 Airy upright.jpg
+
|image=CZ6 - Zeiss LSM 880 Airy inverted.jpg
|stand-name=Zeiss - Axio Imager
+
|stand-name=Zeiss - Axio Observer.Z1
|stand=Upright
+
|stand=Inverted
|microscope=motorized XY stage, motorized Z-drive
+
|microscope=motorized XY stage, motorized Z-drive, Piezo Z stage
 
|obj1=Zeiss Plan-Apochromat 10x 0.45
 
|obj1=Zeiss Plan-Apochromat 10x 0.45
 
|obj2=Zeiss Plan-Apochromat 20x 0.8
 
|obj2=Zeiss Plan-Apochromat 20x 0.8
Line 26: Line 26:
 
|ill1=Fluorescence (Metal Halide, HXP, 120W)
 
|ill1=Fluorescence (Metal Halide, HXP, 120W)
 
|ill2=Transmitted Light (Halogen)
 
|ill2=Transmitted Light (Halogen)
|ill3=Laser Diode 405 nm
+
|ill3=Laser DPSS 355 nm
|ill4=Laser Argon Multiline 458, 477, 488, 514 nm
+
|ill4=Laser Diode 405 nm
|ill5=Laser DPSS 561 nm
+
|ill5=Laser Argon Multiline 458, 477, 488, 496, 514 nm
|ill6=Laser HeNe 594 nm
+
|ill6=Laser DPSS 561 nm
|ill7=Laser HeNe 633 nm
+
|ill7=Laser HeNe 594 nm
 +
|ill8=Laser HeNe 633 nm
 
|detection=32 GaAsP PMT channels <br>
 
|detection=32 GaAsP PMT channels <br>
 
2 PMTs<br>
 
2 PMTs<br>
Line 40: Line 41:
 
|features=simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation, tile scan, multi position scan, spectral scan, Airy scan detection
 
|features=simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation, tile scan, multi position scan, spectral scan, Airy scan detection
 
|software=Zen 2 black
 
|software=Zen 2 black
|incubation=Not available
+
|incubation=Cage incubator (T) + Stage incubator (T+CO2)
|link1=https://docs.google.com/spreadsheets/d/1Ez1kZJetwazShfgL_269vb-v4a8Xf8HGT-0zW551clg/edit?usp=sharing
+
|link1=https://docs.google.com/spreadsheets/d/1gV_odyApUK5cyqumOLOC4yOJrALN_55VRJBrvWzHPNU/edit?usp=sharing
 
}}
 
}}

Revision as of 18:40, 3 February 2016

single photon point scanning confocal system with Quasar detector (32 spectral detection channels in the GaAsP detector plus 2PMTs) and transmitted light detector. Airy scan detector for high resolution imaging. Motorized stage for multi-point acquisition"Zeiss LSM 880 inverted single photon point scanning confocal system with Quasar detector (32 spectral detection channels in the GaAsP detector plus 2PMTs) and transmitted light detector. Airy scan detector for high resolution imaging. Motorized stage for multi-point acquisition" cannot be used as a page name in this wiki.

Suitable for Optical sectioning for 3D reconstruction; fast bleaching samples; high-resolution imaging; multi-color imaging; linear and spectral unmixing of overlapping emission spectra; tile scan; multi position scan; FRAP; FRET.
CZ6 - Zeiss LSM 880 Airy inverted.jpg


Directions

Logo MPI-CBG.jpg
MPI-CBG-Lmf-logo-big.pngMPI-CBG LMF (MPI-CBG, 038A)

Booking

https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py

Details

microscope Zeiss - Axio Observer.Z1, Inverted stand, motorized XY stage, motorized Z-drive, Piezo Z stage
objectives
Zeiss Plan-Apochromat 10x 0.45
Zeiss Plan-Apochromat 20x 0.8
Zeiss LD LCI Plan-Apochromat 25x 0.8 Oil/Glyc/Water DIC
Zeiss W Plan-Apochromat 40x 1.0
Zeiss Plan-Apochromat 63x 1.4 Oil DIC
Zeiss i LCI Plan-Neofluar 63x 1.3 Imm Korr DIC
illumination
Fluorescence (Metal Halide, HXP, 120W)
Transmitted Light (Halogen)
Laser DPSS 355 nm
Laser Diode 405 nm
Laser Argon Multiline 458, 477, 488, 496, 514 nm
Laser DPSS 561 nm
Laser HeNe 594 nm
Laser HeNe 633 nm
detection 32 GaAsP PMT channels

2 PMTs
1 32-channel Airy Scan detector
transmission detector

reflectors Zeiss set 49: DAPI

Zeiss set 38 Endow: GFP
Zeiss set 45: HQ Texas Red

features simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation, tile scan, multi position scan, spectral scan, Airy scan detection
software Zen 2 black
incubation Cage incubator (T) + Stage incubator (T+CO2)