CZ7 - Zeiss LSM 880 Airy upright
From BioDIP
(Difference between revisions)
Line 24: | Line 24: | ||
|obj5=Zeiss Plan-Apochromat 63x 1.4 Oil DIC | |obj5=Zeiss Plan-Apochromat 63x 1.4 Oil DIC | ||
|obj6=Zeiss i LCI Plan-Neofluar 63x 1.3 Imm Korr DIC | |obj6=Zeiss i LCI Plan-Neofluar 63x 1.3 Imm Korr DIC | ||
− | |ill1=Fluorescence (Metal Halide, | + | |ill1=Fluorescence (Metal Halide, HXP, 120W) |
|ill2=Transmitted Light (Halogen) | |ill2=Transmitted Light (Halogen) | ||
|ill3=Laser Diode 405 nm | |ill3=Laser Diode 405 nm | ||
Line 31: | Line 31: | ||
|ill6=Laser HeNe 594 nm | |ill6=Laser HeNe 594 nm | ||
|ill7=Laser HeNe 633 nm | |ill7=Laser HeNe 633 nm | ||
− | |||
|detection='''Single photon detection:''' 2 confocal PMTs with enhanced detection in the red range, GaAsP spectral detector with 32 channels, T-PMT, dichromatic mirrors for excitation/emission splitting, spectral prism sliders for emission detection range selection, common pinhole changeable for each detector setting <br> | |detection='''Single photon detection:''' 2 confocal PMTs with enhanced detection in the red range, GaAsP spectral detector with 32 channels, T-PMT, dichromatic mirrors for excitation/emission splitting, spectral prism sliders for emission detection range selection, common pinhole changeable for each detector setting <br> | ||
'''2 photon detection:''' Two-channel non-descanned GaAsP detector (BiG) set up for emission spectra of EGFP and RFP | '''2 photon detection:''' Two-channel non-descanned GaAsP detector (BiG) set up for emission spectra of EGFP and RFP |
Revision as of 13:33, 3 February 2016
Directions
Booking
https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py
Details
microscope | Zeiss - Axio Imager, Upright stand, motorized XY stage, motorized Z-drive | ||
objectives | |||
illumination | |||
detection | Single photon detection: 2 confocal PMTs with enhanced detection in the red range, GaAsP spectral detector with 32 channels, T-PMT, dichromatic mirrors for excitation/emission splitting, spectral prism sliders for emission detection range selection, common pinhole changeable for each detector setting 2 photon detection: Two-channel non-descanned GaAsP detector (BiG) set up for emission spectra of EGFP and RFP | ||
reflectors | - | ||
features | simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation, tile scan, multi position scan, spectral scan | ||
software | Zen 2010 B | ||
incubation | Not available | ||
links |
| ||
inv.nr. | AIM System 2501000445 10.1.145.41 (IPv4) |