CZ7 - Zeiss LSM 880 Airy upright

From BioDIP
(Difference between revisions)
Jump to: navigation, search
(change all settings info from copied MZ1 to proper CZ7 ones together with Sebastian)
Line 31: Line 31:
 
|ill6=Laser HeNe 594 nm
 
|ill6=Laser HeNe 594 nm
 
|ill7=Laser HeNe 633 nm
 
|ill7=Laser HeNe 633 nm
|detection='''Single photon detection:''' 2 confocal PMTs with enhanced detection in the red range, GaAsP spectral detector with 32 channels, T-PMT, dichromatic mirrors for excitation/emission splitting, spectral prism sliders for emission detection range selection, common pinhole changeable for each detector setting <br>
+
|detection=32 GaAsP PMT channels <br>
'''2 photon detection:''' Two-channel non-descanned GaAsP detector (BiG) set up for emission spectra of EGFP and RFP
+
2 PMTs<br>
|reflectors=-
+
1 32-channel Airy Scan detector <br>
|features=simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation, tile scan, multi position scan, spectral scan
+
transmission detector
|software=Zen 2010 B
+
|reflectors=Zeiss set 49: DAPI<br>
 +
Zeiss set 38 Endow: GFP<br>
 +
Zeiss set 45: HQ Texas Red
 +
|features=simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation, tile scan, multi position scan, spectral scan, Airy scan detection
 +
|software=Zen 2 black
 
|incubation=Not available
 
|incubation=Not available
|link0=https://ifn.mpi-cbg.de/wiki/ifn/index.php/MPI-MZ1_-_Zeiss_2photon_upright_-_startup_%26_shutdown
+
|link1=https://docs.google.com/spreadsheets/d/1Ez1kZJetwazShfgL_269vb-v4a8Xf8HGT-0zW551clg/edit?usp=sharing
|link1=https://docs.google.com/spreadsheet/pub?hl=en_US&hl=en_US&key=0AiAvGnTuH4LedC1CZjIxa05nTnFOM2Ixb0RvdGltaEE&output=html
+
|inv=AIM System 2501000445  10.1.145.41 (IPv4)
+
 
}}
 
}}

Revision as of 13:44, 3 February 2016

Single photon point scanning confocal system with Quasar detector (32 spectral detection channels in the GaAsP detector plus 2PMTs) and transmitted light detector. Airy scan detector for high resolution imaging. Motorized stage for multi-point acquisition"Zeiss LSM 880 upright Single photon point scanning confocal system with Quasar detector (32 spectral detection channels in the GaAsP detector plus 2PMTs) and transmitted light detector. Airy scan detector for high resolution imaging. Motorized stage for multi-point acquisition" cannot be used as a page name in this wiki.

Suitable for Optical sectioning for 3D reconstruction; fast bleaching samples; high-resolution imaging; multi-color imaging; linear and spectral unmixing of overlapping emission spectra; tile scan; multi position scan; FRAP; FRET.
MZ1 - Zeiss 2photon upright.jpg


Directions

Logo MPI-CBG.jpg
MPI-CBG-Lmf-logo-big.pngMPI-CBG LMF (MPI-CBG, 038A)

Booking

https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py

Details

microscope Zeiss - Axio Imager, Upright stand, motorized XY stage, motorized Z-drive
objectives
Zeiss Plan-Apochromat 10x 0.45
Zeiss Plan-Apochromat 20x 0.8
Zeiss LD LCI Plan-Apochromat 25x 0.8 Oil/Glyc/Water DIC
Zeiss W Plan-Apochromat 40x 1.0
Zeiss Plan-Apochromat 63x 1.4 Oil DIC
Zeiss i LCI Plan-Neofluar 63x 1.3 Imm Korr DIC
illumination
Fluorescence (Metal Halide, HXP, 120W)
Transmitted Light (Halogen)
Laser Diode 405 nm
Laser Argon Multiline 458, 477, 488, 514 nm
Laser DPSS 561 nm
Laser HeNe 594 nm
Laser HeNe 633 nm
detection 32 GaAsP PMT channels

2 PMTs
1 32-channel Airy Scan detector
transmission detector

reflectors Zeiss set 49: DAPI

Zeiss set 38 Endow: GFP
Zeiss set 45: HQ Texas Red

features simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation, tile scan, multi position scan, spectral scan, Airy scan detection
software Zen 2 black
incubation Not available
links
  • [ beam path]
  • [ advanced system check]
inv.nr.



Personal tools