Gallery

From BioDIP
(Difference between revisions)
Jump to: navigation, search
m
m
Line 2: Line 2:
  
 
=== overview images ===
 
=== overview images ===
 +
 +
* Typical overview image of a tissue sample region. Pinhole diameter decreases from 8 airy units to 1 airy unit.
  
 
[[Image:Confocaldualcolor_8.jpg|100px]]
 
[[Image:Confocaldualcolor_8.jpg|100px]]
Line 11: Line 13:
 
[[Image:Confocaldualcolor_2.jpg|100px]]
 
[[Image:Confocaldualcolor_2.jpg|100px]]
 
[[Image:Confocaldualcolor_1.jpg|100px]]
 
[[Image:Confocaldualcolor_1.jpg|100px]]
 +
 +
* Invitrogen FluoCells(r) #4, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 488 nm + 594 nm excitation, 505-580 nm + LP610 nm detection
  
 
=== XY ===
 
=== XY ===
Line 27: Line 31:
 
[[Image:63xinvitrogen-4-PH0.6.jpg|100px]]
 
[[Image:63xinvitrogen-4-PH0.6.jpg|100px]]
  
* Invitrogen FluoCells(r) #4, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 594nm excitation, LP610nm detection
+
* Invitrogen FluoCells(r) #4, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 594 nm excitation, LP610 nm detection
  
 
=== XYZ ===
 
=== XYZ ===
Line 43: Line 47:
 
[[Image:Pinholeseries_1.jpg|100px]]
 
[[Image:Pinholeseries_1.jpg|100px]]
  
* Invitrogen FluoCells(r) #4, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 488nm excitation, 505-580nm detection, 0.2µm Z-stepsize, Bitplane Imaris
+
* Invitrogen FluoCells(r) #4, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 488 nm excitation, 505-580 nm detection, 0.2 µm Z-stepsize, Bitplane Imaris
  
 
== Cleaning an objective makes sense ==
 
== Cleaning an objective makes sense ==

Revision as of 14:57, 23 April 2009

Contents

Effect of the CLSM pinhole

overview images

  • Typical overview image of a tissue sample region. Pinhole diameter decreases from 8 airy units to 1 airy unit.

Confocaldualcolor 8.jpg Confocaldualcolor 7.jpg Confocaldualcolor 6.jpg Confocaldualcolor 5.jpg Confocaldualcolor 4.jpg Confocaldualcolor 3.jpg Confocaldualcolor 2.jpg Confocaldualcolor 1.jpg

  • Invitrogen FluoCells(r) #4, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 488 nm + 594 nm excitation, 505-580 nm + LP610 nm detection

XY

  • High resolution image, acquired with decreasing pinhole diameter from 8 airy units to 0.6 airy units.

63xinvitrogen-4-PH8.jpg 63xinvitrogen-4-PH7.jpg 63xinvitrogen-4-PH6.jpg 63xinvitrogen-4-PH5.jpg 63xinvitrogen-4-PH4.jpg 63xinvitrogen-4-PH3.jpg 63xinvitrogen-4-PH2.jpg 63xinvitrogen-4-PH1.jpg 63xinvitrogen-4-PH0.8.jpg 63xinvitrogen-4-PH0.6.jpg

  • Invitrogen FluoCells(r) #4, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 594 nm excitation, LP610 nm detection

XYZ

  • One region of the sample was imaged with decreasing pinhole diameter, starting from 9 airy units (first image) down to 1 airy units (last image).

Pinholeseries 9.jpg Pinholeseries 8.jpg Pinholeseries 7.jpg Pinholeseries 6.jpg Pinholeseries 5.jpg Pinholeseries 4.jpg Pinholeseries 3.jpg Pinholeseries 2.jpg Pinholeseries 1.jpg

  • Invitrogen FluoCells(r) #4, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 488 nm excitation, 505-580 nm detection, 0.2 µm Z-stepsize, Bitplane Imaris

Cleaning an objective makes sense

  • First image taken w/o cleaning the lens. Second image after two wipes with Whatman(r) paper and cleaning agent.

dirty clean

  • Invitrogen FluoCells(r) #6, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 488nm excitation, 505-550nm detection, pinhole @98µm