Gallery

From BioDIP
(Difference between revisions)
Jump to: navigation, search
m
Line 1: Line 1:
== Effect of the CLSM pinhole ==
+
== Images acquired with our equipment ==
  
=== overview images ===
+
=== Effect of the CLSM pinhole ===
 +
 
 +
==== overview images ====
  
 
* Typical overview image of a tissue sample region. Pinhole diameter decreases from 8 airy units to 1 airy unit.
 
* Typical overview image of a tissue sample region. Pinhole diameter decreases from 8 airy units to 1 airy unit.
Line 19: Line 21:
 
* Invitrogen FluoCells(r) #4, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 488 nm + 594 nm excitation, 505-580 nm + LP610 nm detection
 
* Invitrogen FluoCells(r) #4, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 488 nm + 594 nm excitation, 505-580 nm + LP610 nm detection
  
=== XY ===
+
==== XY ====
  
 
* High resolution image, acquired with decreasing pinhole diameter from 8 airy units to 0.6 airy units.
 
* High resolution image, acquired with decreasing pinhole diameter from 8 airy units to 0.6 airy units.
Line 39: Line 41:
 
* Invitrogen FluoCells(r) #4, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 594 nm excitation, LP610 nm detection
 
* Invitrogen FluoCells(r) #4, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 594 nm excitation, LP610 nm detection
  
=== XYZ ===
+
==== XYZ ====
  
 
* One region of the sample was imaged with decreasing pinhole diameter, starting from 8 airy units (first image) down to 1 airy units (last image).
 
* One region of the sample was imaged with decreasing pinhole diameter, starting from 8 airy units (first image) down to 1 airy units (last image).
Line 57: Line 59:
 
* Invitrogen FluoCells(r) #4, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 488 nm excitation, 505-580 nm detection, 0.2 µm Z-stepsize, Bitplane Imaris
 
* Invitrogen FluoCells(r) #4, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 488 nm excitation, 505-580 nm detection, 0.2 µm Z-stepsize, Bitplane Imaris
  
== Cleaning an objective makes sense ==
+
=== Cleaning an objective makes sense ===
  
 
<gallery perrow=2>
 
<gallery perrow=2>

Revision as of 16:34, 7 September 2009

Contents

Images acquired with our equipment

Effect of the CLSM pinhole

overview images

  • Typical overview image of a tissue sample region. Pinhole diameter decreases from 8 airy units to 1 airy unit.
  • Available as Video
  • Invitrogen FluoCells(r) #4, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 488 nm + 594 nm excitation, 505-580 nm + LP610 nm detection

XY

  • High resolution image, acquired with decreasing pinhole diameter from 8 airy units to 0.6 airy units.
  • Available as Video
  • Invitrogen FluoCells(r) #4, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 594 nm excitation, LP610 nm detection

XYZ

  • One region of the sample was imaged with decreasing pinhole diameter, starting from 8 airy units (first image) down to 1 airy units (last image).
  • Available as Video
  • Invitrogen FluoCells(r) #4, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 488 nm excitation, 505-580 nm detection, 0.2 µm Z-stepsize, Bitplane Imaris

Cleaning an objective makes sense

  • Invitrogen FluoCells(r) #6, Zeiss LSM 510, Plan-Apochromat 63x/1.4, 488nm excitation, 505-550nm detection, pinhole @98µm
Personal tools