Grid LSM & WF, upr., BIOTEC
From BioDIP
(Difference between revisions)
Line 16: | Line 16: | ||
|obj2=Zeiss Achroplan 40x 0.8 W | |obj2=Zeiss Achroplan 40x 0.8 W | ||
|obj3=Zeiss C-Apochromat 40x 1.2 W | |obj3=Zeiss C-Apochromat 40x 1.2 W | ||
− | |||
|obj5=Zeiss Plan-Apochromat 63x 1.4 Oil | |obj5=Zeiss Plan-Apochromat 63x 1.4 Oil | ||
|obj6=Zeiss Plan-Apochromat 100x 1.4 Oil | |obj6=Zeiss Plan-Apochromat 100x 1.4 Oil | ||
|obj7=Zeiss alpha Plan-Fluar 100x 1.45 Oil | |obj7=Zeiss alpha Plan-Fluar 100x 1.45 Oil | ||
− | |||
|ill1=Fluorescence (HBO) | |ill1=Fluorescence (HBO) | ||
|ill2=Transmitted Light (Halogen) | |ill2=Transmitted Light (Halogen) | ||
|ill3=Laser DPSS 488 nm | |ill3=Laser DPSS 488 nm | ||
|ill4=Laser DPSS 561 nm | |ill4=Laser DPSS 561 nm | ||
− | |||
− | |||
− | |||
− | |||
|detection=widefield fluorescence with EMCCD, multi point scanner with EMCCD, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, variable size pinholes for confocal detection | |detection=widefield fluorescence with EMCCD, multi point scanner with EMCCD, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, variable size pinholes for confocal detection | ||
|reflectors=Analysator<br>GFP : EX 470/40 ; BS 495 ; EM 525/50<br>FITC : EX 480/20 ; BS 495 ; EM 535/40<br>TxRed : EX 570/20 ; BS 590 ; EM 640/40<br>DAPI (A) : EX 350/50 ; BS 400 ; EM LP 460/50<br>empty<br>empty | |reflectors=Analysator<br>GFP : EX 470/40 ; BS 495 ; EM 525/50<br>FITC : EX 480/20 ; BS 495 ; EM 535/40<br>TxRed : EX 570/20 ; BS 590 ; EM 640/40<br>DAPI (A) : EX 350/50 ; BS 400 ; EM LP 460/50<br>empty<br>empty |
Revision as of 17:35, 16 September 2009
Directions
[[image:|150px|text-bottom|right]]
Booking
https://techpool.biotec.tu-dresden.de/schedule/schedule.php?scheduleid=sc142df4c59eef5c
Details
microscope | , Upright stand, motorized XY stage, Z-Piezo stage, fluorescence, transmitted light with manual DIC | ||
objectives | |||
illumination | |||
detection | widefield fluorescence with EMCCD, multi point scanner with EMCCD, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, variable size pinholes for confocal detection | ||
reflectors | Analysator GFP : EX 470/40 ; BS 495 ; EM 525/50 FITC : EX 480/20 ; BS 495 ; EM 535/40 TxRed : EX 570/20 ; BS 590 ; EM 640/40 DAPI (A) : EX 350/50 ; BS 400 ; EM LP 460/50 empty empty | ||
features | widefield fluoerescence imaging, confocal imaging, simultaneous GFP/RFP imaging, sequential imaging, Z stacks, time-series, advanced time-series, averaging, summarizing | ||
software | |||
incubation | stage incubator (T) | ||
links |
| ||
inv.nr. | 0 |