|description=Structured Illumination Superresolution and fast widefield. 4x EM-DDC camera (sCMOS soon), 4x laser illumination widefield or structured 3D illumination
 
|description=Structured Illumination Superresolution and fast widefield. 4x EM-DDC camera (sCMOS soon), 4x laser illumination widefield or structured 3D illumination
|applications= super resolution down to 120 nm, and fast widefield imaging.  
+
|applications=super resolution down to 120 nm, and fast widefield imaging.
|image=
+
|stand-name=Leica - DMRE
|stand-name=Applied Precision OMX
+
 
|stand=Inverted
 
|stand=Inverted
 
|microscope=nano precise XYZ stage, fluorescence, transmitted light, DIC
 
|microscope=nano precise XYZ stage, fluorescence, transmitted light, DIC
|obj1=Olympus 100x 1.4 oil Plan-Apochromat 10x 0.45
 
 
|ill1=Transmitted Light (LED)
 
|ill1=Transmitted Light (LED)
|ill2=Laser diode 405 nm
 
|ill3=Laser diode 488 nm
 
|ill4=Laser diode 561 nm
 
|ill5=Laser diode 633 nm
 
 
|detection=4x EM-CCD (soon to ve sCMOS instead)
 
|detection=4x EM-CCD (soon to ve sCMOS instead)
|reflectors=EX 358-371, EM LP397 (Zeiss FS01wf)<br>EX 473-490, EM 495-647 (Zeiss FS09wf)<br>EX 542-554, EM LP592 (Zeiss FS15wf)
+
|reflectors=standard set, OMX. See Docs at OMX.
|features=simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation
+
|features=fast 4 colour widefield. Super resolution by structured illumination in 3D, down to just over 100 nm resolution (2x the resolution of conventional light microscopy)
|software=-
+
|software=API softworx and OMX software for driving the scope and super resolution reconstruction.
|incubation=Not available
+
|incubation=Stage incubator (T) + objective heater
|link1=http://spreadsheets.google.com/pub?key=pFf3a5iBejjDqCEHnuP4NNQ
+
|inv= MOZG040809900
|link2=https://spreadsheets.google.com/pub?key=pMZJXCgd5HNu7RvHsg75fMA
+
|facility_image=Logo-lmf.jpg
|inv=403145 SIP:55228
+
 
|objectives=10x/0.45 Apo<br>25x/0.8 Imm Corr<br>20x/0.5 Ph2 Dipping<br>40x/1.2 W Apo<br>40x/1.3 Oil<br>40x/0.8 W Dipping<br>63x/1.4 Oil Apo<br>100x/1.4 Oil Apo
 
|objectives=10x/0.45 Apo<br>25x/0.8 Imm Corr<br>20x/0.5 Ph2 Dipping<br>40x/1.2 W Apo<br>40x/1.3 Oil<br>40x/0.8 W Dipping<br>63x/1.4 Oil Apo<br>100x/1.4 Oil Apo
 
|illumination=Halogen<br>HBO<br>458, 477, 488, 514 nm Argon laser<br>543 nm HeNe laser<br>633 nm HeNe laser
 
|illumination=Halogen<br>HBO<br>458, 477, 488, 514 nm Argon laser<br>543 nm HeNe laser<br>633 nm HeNe laser
 
}}
 
}}

Revision as of 17:36, 2 May 2011

Suitable for super resolution down to 120 nm, and fast widefield imaging..
[[image:|250px]]


Directions

[[image:|150px|text-bottom|right]]

[[image:|100px]] MPI-CBG LMF (MPI-CBG, 036)

Booking

https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py

Details

microscope Leica - DMRE, Inverted stand, nano precise XYZ stage, fluorescence, transmitted light, DIC
objectives
illumination
Transmitted Light (LED)
detection 4x EM-CCD (soon to ve sCMOS instead)
reflectors standard set, OMX. See Docs at OMX.
features fast 4 colour widefield. Super resolution by structured illumination in 3D, down to just over 100 nm resolution (2x the resolution of conventional light microscopy)
software API softworx and OMX software for driving the scope and super resolution reconstruction.
incubation Stage incubator (T) + objective heater
links
  • [ manual]
  • [ laser power values]
  • [ beam path]
  • [ advanced system check]