H1 - DeltaVision OMX - pDV
From BioDIP
(Difference between revisions)
(add OMX info) |
|||
Line 3: | Line 3: | ||
|system-name=DeltaVision OMX - pDV | |system-name=DeltaVision OMX - pDV | ||
|type=Microscope | |type=Microscope | ||
− | |category= | + | |category=Laser Scanning Confocal |
|facility=MPI-CBG LMF | |facility=MPI-CBG LMF | ||
|building=MPI-CBG | |building=MPI-CBG | ||
|room=036 | |room=036 | ||
− | |||
|description=Structured Illumination Superresolution and fast widefield. 4x EM-DDC camera (sCMOS soon), 4x laser illumination widefield or structured 3D illumination | |description=Structured Illumination Superresolution and fast widefield. 4x EM-DDC camera (sCMOS soon), 4x laser illumination widefield or structured 3D illumination | ||
− | |applications= super resolution down to 120 nm, and fast widefield imaging. | + | |applications=super resolution down to 120 nm, and fast widefield imaging. |
− | + | |stand-name=Leica - DMRE | |
− | |stand-name= | + | |
|stand=Inverted | |stand=Inverted | ||
|microscope=nano precise XYZ stage, fluorescence, transmitted light, DIC | |microscope=nano precise XYZ stage, fluorescence, transmitted light, DIC | ||
− | |||
|ill1=Transmitted Light (LED) | |ill1=Transmitted Light (LED) | ||
− | |||
− | |||
− | |||
− | |||
|detection=4x EM-CCD (soon to ve sCMOS instead) | |detection=4x EM-CCD (soon to ve sCMOS instead) | ||
− | |reflectors= | + | |reflectors=standard set, OMX. See Docs at OMX. |
− | |features= | + | |features=fast 4 colour widefield. Super resolution by structured illumination in 3D, down to just over 100 nm resolution (2x the resolution of conventional light microscopy) |
− | |software= | + | |software=API softworx and OMX software for driving the scope and super resolution reconstruction. |
− | |incubation= | + | |incubation=Stage incubator (T) + objective heater |
− | | | + | |inv= MOZG040809900 |
− | | | + | |facility_image=Logo-lmf.jpg |
− | + | ||
|objectives=10x/0.45 Apo<br>25x/0.8 Imm Corr<br>20x/0.5 Ph2 Dipping<br>40x/1.2 W Apo<br>40x/1.3 Oil<br>40x/0.8 W Dipping<br>63x/1.4 Oil Apo<br>100x/1.4 Oil Apo | |objectives=10x/0.45 Apo<br>25x/0.8 Imm Corr<br>20x/0.5 Ph2 Dipping<br>40x/1.2 W Apo<br>40x/1.3 Oil<br>40x/0.8 W Dipping<br>63x/1.4 Oil Apo<br>100x/1.4 Oil Apo | ||
|illumination=Halogen<br>HBO<br>458, 477, 488, 514 nm Argon laser<br>543 nm HeNe laser<br>633 nm HeNe laser | |illumination=Halogen<br>HBO<br>458, 477, 488, 514 nm Argon laser<br>543 nm HeNe laser<br>633 nm HeNe laser | ||
}} | }} |
Revision as of 17:36, 2 May 2011
[[image:|250px]] |
Directions
[[image:|150px|text-bottom|right]]
Booking
https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py
Details
microscope | Leica - DMRE, Inverted stand, nano precise XYZ stage, fluorescence, transmitted light, DIC | ||
objectives |
| ||
illumination | |||
detection | 4x EM-CCD (soon to ve sCMOS instead) | ||
reflectors | standard set, OMX. See Docs at OMX. | ||
features | fast 4 colour widefield. Super resolution by structured illumination in 3D, down to just over 100 nm resolution (2x the resolution of conventional light microscopy) | ||
software | API softworx and OMX software for driving the scope and super resolution reconstruction. | ||
incubation | Stage incubator (T) + objective heater | ||
links |
| ||
inv.nr. | MOZG040809900 |