| detection = Hamamatsu Camera ORCA ER, progressive scan interline CCD, 1344 x 1024 pixels, 6.45 um pixel size, 14.75 MHz digitization, 8 e- rms readout noise, 8 fps @ full frame, 18.000 e- full well capacity, 2250:1 dynamic range, peltier cooling (-20 degrees C @ 20 degrees C ambient), 12 bit ADC, 0.1 electron/pixel/sec dark current, up to 10x analog gain, offset functions | | detection = Hamamatsu Camera ORCA ER, progressive scan interline CCD, 1344 x 1024 pixels, 6.45 um pixel size, 14.75 MHz digitization, 8 e- rms readout noise, 8 fps @ full frame, 18.000 e- full well capacity, 2250:1 dynamic range, peltier cooling (-20 degrees C @ 20 degrees C ambient), 12 bit ADC, 0.1 electron/pixel/sec dark current, up to 10x analog gain, offset functions | ||
| reflectors = MT20 Excitation Unit<br> - EXCITATION FILTERS <br> 403/ 492 / 572 / 387/ 485 / 560/ 650 <br> | | reflectors = MT20 Excitation Unit<br> - EXCITATION FILTERS <br> 403/ 492 / 572 / 387/ 485 / 560/ 650 <br> | ||
− | - DICHROICS AND EMISSION FILTERS <br> * POSITION 1: < | + | - DICHROICS AND EMISSION FILTERS <br> * POSITION 1: <br> D 405-435/450-485/510-550/590-675 <br>X 450-475/515-545/600-665 <br> * POSITION 2:<BR> D QBP 410-465, 504-538, 581-632, 669-743 <BR> M QBP 415-461, 507-533, 586-625, 673-722 <BR> * POSITION 3: EMPTY <BR> * POSITION 4: EMPTY<BR> * POSITION 5:<BR> D 485-570/605-690<br> X500-560/615-675<br> * POSITION 6<BR> D 440-490/510-575/610-675 <br>X 450-480/525-560/615-660 |
− | | features = - | + | | features = -< |
| incubation = cage incubator with temperature and CO2 control capabilities | | incubation = cage incubator with temperature and CO2 control capabilities | ||
| link1 = - | | link1 = - |
Revision as of 17:27, 21 October 2008
Directions
[[image:|150px|text-bottom|right]]
Booking
https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py
Details
microscope | , Inverted stand, motorized XY stage, motorized Z-drive, fluorescence, transmitted light | ||
objectives |
| ||
illumination |
| ||
detection | Hamamatsu Camera ORCA ER, progressive scan interline CCD, 1344 x 1024 pixels, 6.45 um pixel size, 14.75 MHz digitization, 8 e- rms readout noise, 8 fps @ full frame, 18.000 e- full well capacity, 2250:1 dynamic range, peltier cooling (-20 degrees C @ 20 degrees C ambient), 12 bit ADC, 0.1 electron/pixel/sec dark current, up to 10x analog gain, offset functions | ||
reflectors | MT20 Excitation Unit - EXCITATION FILTERS 403/ 492 / 572 / 387/ 485 / 560/ 650 - DICHROICS AND EMISSION FILTERS | ||
features | -<"-<" cannot be used as a page name in this wiki. | ||
software | |||
incubation | cage incubator with temperature and CO2 control capabilities | ||
links |
| ||
inv.nr. | 405679 |
[[Category:{{{type}}}]]