LSM 510, inverse, BIOTEC
From BioDIP
(Difference between revisions)
m (Bioz01 moved to Bioz01 - Zeiss LSM 510) |
|||
Line 11: | Line 11: | ||
| description = Our Zeiss LSM 510 is designed for routine work and dedicated for high resolution imaging in XYZ. The laser lines are well distributed over the spectrum and especially good for common dye combinations. Due to the conventional setup, it's straight forward to work with. | | description = Our Zeiss LSM 510 is designed for routine work and dedicated for high resolution imaging in XYZ. The laser lines are well distributed over the spectrum and especially good for common dye combinations. Due to the conventional setup, it's straight forward to work with. | ||
| microscope = inverted stand, motorized XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | | microscope = inverted stand, motorized XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | ||
− | | objectives = 10x/0.3 | + | | objectives = 10x/0.3<br>20x/0.5<br>40x/1.2 W corr<br>100x/1.4 Oil DIC |
| illumination = HBO lamp<br>Halogen lamp<br>405 diode laser<br>458, 477(optional), 488, 514 argon laser<br>543 HeNe laser<br>633 HeNe laser | | illumination = HBO lamp<br>Halogen lamp<br>405 diode laser<br>458, 477(optional), 488, 514 argon laser<br>543 HeNe laser<br>633 HeNe laser | ||
| detection = point scanner, 2 confocal PMTs, 1 META detector, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector | | detection = point scanner, 2 confocal PMTs, 1 META detector, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector |
Revision as of 14:54, 27 June 2008
Directions
[[image:|150px|text-bottom|right]]
Booking
https://techpool.biotec.tu-dresden.de/schedule/schedule.php?scheduleid=sc142df4c59eef5c
Details
microscope | , inverted stand, inverted stand, motorized XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | ||
objectives |
| ||
illumination |
| ||
detection | point scanner, 2 confocal PMTs, 1 META detector, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector | ||
reflectors | DAPI : EX 365/12 ; BS 395 ; EM LP 397 FITC : EX 470/40 ; BS 510 ; EM LP 515 TRITC : EX 546/12 ; BS 580 ; EM LP 590 LP | ||
features | simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation, FRAP | ||
software | |||
incubation | none | ||
links |
| ||
inv.nr. |
[[Category:{{{type}}}]]