LSM 510, inverse, BIOTEC

From BioDIP
(Difference between revisions)
Jump to: navigation, search
Line 8: Line 8:
 
|room=221
 
|room=221
 
|facility_image=Imaging@Biotec.jpg
 
|facility_image=Imaging@Biotec.jpg
 +
|logo_image=Logo_Biotec.jpg
 
|description=Our [[Zeiss LSM 510]] [[confocal]] laser scanning microscope is designed for routine work and dedicated for high resolution imaging in XYZ. The laser lines are well distributed over the spectrum and especially good for common dye combinations. Due to the conventional setup, it's straight forward to work with.
 
|description=Our [[Zeiss LSM 510]] [[confocal]] laser scanning microscope is designed for routine work and dedicated for high resolution imaging in XYZ. The laser lines are well distributed over the spectrum and especially good for common dye combinations. Due to the conventional setup, it's straight forward to work with.
 
|applications=- confocal scanning microscopy
 
|applications=- confocal scanning microscopy

Revision as of 16:02, 24 November 2010

Suitable for - confocal scanning microscopy.
Bioz01.jpg


Directions

[[image:|150px|text-bottom|right]]

[[image:|100px]] Imaging@Biotec"Imaging@Biotec" is not in the list of possible values (DZNE - Imaging Platform, EM- and Histo-Facility CRTD / BIOTEC, Image Processing@BIOTEC, Imaging@BIOTEC/CRTD, MPI-CBG LMF, MPI-CBG LMF - Quantitative Image Analysis Unit, MPI-CBG TDS, MTZ Imaging, MPI-CBG EM, BioDIP) for this property. ("Biotec" is not in the list of possible values (BIOTEC, CRTD, DZNE, MTZ, MPI-CBG) for this property., 221)

Booking

https://techpool.biotec.tu-dresden.de/schedule/schedule.php?scheduleid=sc142df4c59eef5c

Details

microscope Zeiss - Axiovert 200M, Inverted stand, inverted stand, motorized XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC
objectives
Zeiss EC Plan-Neofluar 10x 0.3
Zeiss EC Plan-Neofluar 20x 0.5
Zeiss C-Apochromat 40x 1.2 W
Zeiss C-Apochromat 63x 1.2 W
Zeiss Plan-Apochromat 63x 1.4 Oil
Zeiss alpha Plan-Fluar 100x 1.45 Oil
illumination
Transmitted Light (Halogen)
Fluorescence (HBO)
Laser Diode 405 nm
Laser Argon Multiline 458, 477, 488, 514 nm
Laser HeNe 543 nm
Laser HeNe 633 nm
detection point scanner, 2 confocal PMTs, 1 META detector, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector
reflectors empty
DAPI : EX 365/12 ; BS 395 ; EM LP 397
FITC : EX 470/40 ; BS 510 ; EM LP 515
TRITC : EX 546/12 ; BS 580 ; EM LP 590 LP
empty
empty
features simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation, FRAP
software Zeiss AIM
incubation Stage incubator (T)
links
  • [- beam path]
  • [ advanced system check]
inv.nr. -