LSM 510, inverse, BIOTEC
From BioDIP
(Difference between revisions)
Line 10: | Line 10: | ||
| description = Our Zeiss LSM 510 is designed for routine work and dedicated for high resolution imaging in XYZ. The laser lines are well distributed over the spectrum and especially good for common dye combinations. Due to the conventional setup, it's straight forward to work with. | | description = Our Zeiss LSM 510 is designed for routine work and dedicated for high resolution imaging in XYZ. The laser lines are well distributed over the spectrum and especially good for common dye combinations. Due to the conventional setup, it's straight forward to work with. | ||
| microscope = inverted stand, motorized XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | | microscope = inverted stand, motorized XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | ||
+ | | objectives = 10x/0.3<br>10x/0.45 W<br>20x/0.5<br>40x/1.2 W corr<br>100x/1.4 Oil DIC | ||
| excitation = laser (nm): 405, 458, 477(optional), 488, 514, 543, 633 | | excitation = laser (nm): 405, 458, 477(optional), 488, 514, 543, 633 | ||
| detection = point scanner, 2 confocal PMTs, 1 META detector, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector | | detection = point scanner, 2 confocal PMTs, 1 META detector, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector | ||
| features = simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation, FRAP | | features = simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation, FRAP | ||
}} | }} |
Revision as of 11:42, 16 June 2008
[[image:|250px]] |
Directions
[[image:|150px|text-bottom|right]]
Booking
https://techpool.biotec.tu-dresden.de/schedule/schedule.php?scheduleid=sc142df4c59eef5c
Details
microscope | , stand, inverted stand, motorized XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | ||
objectives |
| ||
illumination |
| ||
detection | point scanner, 2 confocal PMTs, 1 META detector, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector | ||
reflectors | |||
features | simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation, FRAP | ||
software | |||
incubation | |||
links |
| ||
inv.nr. |
[[Category:{{{type}}}]]