LSM 780/FCS, inverse, BIOTEC

From BioDIP
(Difference between revisions)
Jump to: navigation, search
Line 7: Line 7:
 
|building=BIOTEC
 
|building=BIOTEC
 
|room=221
 
|room=221
|description=It is an inverted Laser Scanning Confocal microscope with up to 10 spectral detection channels and one transmission channel. It provides F(C)CS functionality by the Confocr3 module. For FCS please ask Wolfgang Staroske.
+
|description=It is an inverted Laser Scanning Confocal microscope with up to 32 spectral detection channels, 2 PMTs and one transmission channel. It provides F(C)CS functionality by the Confocr3 module. For FCS please ask Wolfgang Staroske.
 
|applications=the detection of multiple fluorescent dyes, FRAP, FRET, optical sectioning for 3D reconstruction, linear and spectral unmixing of overlapping emission spectra. It can acquire brightfield and DIC images with the transmission detector.
 
|applications=the detection of multiple fluorescent dyes, FRAP, FRET, optical sectioning for 3D reconstruction, linear and spectral unmixing of overlapping emission spectra. It can acquire brightfield and DIC images with the transmission detector.
 
|image=Zeiss LSM 780.jpg
 
|image=Zeiss LSM 780.jpg
Line 17: Line 17:
 
|obj3=Zeiss Plan-Apochromat 40x 0,95 korr.
 
|obj3=Zeiss Plan-Apochromat 40x 0,95 korr.
 
|obj4=Zeiss C-Apochromat 40x 1.2 W
 
|obj4=Zeiss C-Apochromat 40x 1.2 W
|obj5=Zeiss Plan-Apochromat 63x 1.4 Oil
+
|obj5=Zeiss C-Apochromat 63x 1.2 W
|obj6=Zeiss C-Apochromat 63x 1.2 W
+
|obj6=Zeiss Plan-Apochromat 63x 1.4 Oil
 
|ill1=Laser Diode 405 nm
 
|ill1=Laser Diode 405 nm
 
|ill2=Laser Argon Multiline 458, 488, 514 nm
 
|ill2=Laser Argon Multiline 458, 488, 514 nm
Line 26: Line 26:
 
|ill6=Fluorescence (HBO)
 
|ill6=Fluorescence (HBO)
 
|ill7=Transmitted Light (Halogen)
 
|ill7=Transmitted Light (Halogen)
|detection=34 PMT channels
+
|detection=32 PMT channels (GaAsP)
 +
2 PMTs
 
transmission detector
 
transmission detector
GaAsP detector
 
 
|reflectors=Zeiss set 49: DAPI
 
|reflectors=Zeiss set 49: DAPI
 
Zeiss set 38: GFP
 
Zeiss set 38: GFP

Revision as of 18:18, 8 November 2010

Suitable for the detection of multiple fluorescent dyes, FRAP, FRET, optical sectioning for 3D reconstruction, linear and spectral unmixing of overlapping emission spectra. It can acquire brightfield and DIC images with the transmission detector..
Zeiss LSM 780.jpg


Directions

[[image:|150px|text-bottom|right]]

[[image:|100px]] Imaging@Biotec"Imaging@Biotec" is not in the list of possible values (DZNE - Imaging Platform, EM- and Histo-Facility CRTD / BIOTEC, Image Processing@BIOTEC, Imaging@BIOTEC/CRTD, MPI-CBG LMF, MPI-CBG LMF - Quantitative Image Analysis Unit, MPI-CBG TDS, MTZ Imaging, MPI-CBG EM, BioDIP) for this property. (BIOTEC, 221)

Booking

https://techpool.biotec.tu-dresden.de/schedule/schedule.php?scheduleid=sc142df4c59eef5c

Details

microscope Zeiss - Axio Observer, Inverted stand, -
objectives
Zeiss EC Plan-Neofluar 10x 0.3
Zeiss EC Plan-Neofluar 20x 0.5
Zeiss Plan-Apochromat 40x 0,95 korr.
Zeiss C-Apochromat 40x 1.2 W
Zeiss C-Apochromat 63x 1.2 W
Zeiss Plan-Apochromat 63x 1.4 Oil
illumination
Laser Diode 405 nm
Laser Argon Multiline 458, 488, 514 nm
Laser DPSS 561 nm
Laser HeNe 594 nm
Laser HeNe 633 nm
Fluorescence (HBO)
Transmitted Light (Halogen)
detection 32 PMT channels (GaAsP)

2 PMTs transmission detector

reflectors Zeiss set 49: DAPI

Zeiss set 38: GFP Zeiss set 43: Cy3 Zeiss set 50: Cy5

features F(C)CS with ConfoCor 3 unit
software Zen 2010
incubation Not available
links
  • [ manual]
  • [ laser power values]
  • [ beam path]
  • [ advanced system check]
inv.nr. 0