LSM 780/FLIM, inverse, CRTD

From BioDIP
(Difference between revisions)
Jump to: navigation, search
 
(12 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 
{{Equipment
 
{{Equipment
|system-number=BIO16
+
|system-number=BIO14
 
|system-name=LSM 780/FLIM, inverse, CRTD
 
|system-name=LSM 780/FLIM, inverse, CRTD
 
|type=Microscope
 
|type=Microscope
 
|category=Laser Scanning Confocal
 
|category=Laser Scanning Confocal
|facility=Imaging@Biotec
+
|facility=Imaging@BIOTEC/CRTD
 
|building=CRTD
 
|building=CRTD
 
|room=-1.124
 
|room=-1.124
Line 10: Line 10:
 
|Institute-logo=CRTD logo.PNG
 
|Institute-logo=CRTD logo.PNG
 
|description=It is an inverted Laser Scanning Confocal microscope with up to 32 spectral detection channels, 2 PMTs and one transmission channel. It provides FLIM functionality.
 
|description=It is an inverted Laser Scanning Confocal microscope with up to 32 spectral detection channels, 2 PMTs and one transmission channel. It provides FLIM functionality.
|applications=Suitable for the detection of multiple fluorescent dyes, FRAP, FRET, optical sectioning for 3D reconstruction, linear and spectral unmixing of overlapping emission spectra. It can acquire brightfield and DIC images with the transmission detector
+
|applications=the detection of multiple fluorescent dyes (but no DAPI), FRAP, FRET, optical sectioning for 3D reconstruction, linear and spectral unmixing of overlapping emission spectra. It can acquire brightfield and DIC images with the transmission detector
 +
|image=LSM780FLIM inverse CRTD.jpg
 
|stand-name=Zeiss - Axio Observer
 
|stand-name=Zeiss - Axio Observer
 
|stand=Inverted
 
|stand=Inverted
Line 17: Line 18:
 
|obj2=Zeiss Plan-Apochromat 20x 0.8
 
|obj2=Zeiss Plan-Apochromat 20x 0.8
 
|obj3=Zeiss C-Apochromat 40x 1.2 W
 
|obj3=Zeiss C-Apochromat 40x 1.2 W
|obj4=Zeiss alpha Plan-Apochromat 100x 1,46 oil
+
|obj5=Zeiss alpha Plan-Apochromat 63x 1.46 Oil
 
|ill1=Laser Diode 440 nm (pulsed)
 
|ill1=Laser Diode 440 nm (pulsed)
 
|ill2=Laser Diode 475 nm (pulsed)
 
|ill2=Laser Diode 475 nm (pulsed)
Line 30: Line 31:
 
|reflectors=Zeiss set 49: DAPI <br>
 
|reflectors=Zeiss set 49: DAPI <br>
 
Zeiss set 38: GFP <br>
 
Zeiss set 38: GFP <br>
 +
Zeiss set 47: CFP <br>
 +
Zeiss set 46: YFP <br>
 
Zeiss set 43: Cy3
 
Zeiss set 43: Cy3
|features=spectral scan, FLIM (B&H) unit
+
|features=spectral scan, FLIM dual channel unit from B&H
|software=ZEN 2011
+
|software=ZEN black 2011
|incubation=Cage incubator (T+CO2)
+
|incubation=Cage incubator (T+CO2+Humidity)
|inv=0
+
|link1=https://www.biotec.tu-dresden.de/lmf-wiki/index.php/Laser_Power_LSM780/FLIM
 +
|inv=84844
 
}}
 
}}

Latest revision as of 13:54, 17 October 2014

Suitable for the detection of multiple fluorescent dyes (but no DAPI), FRAP, FRET, optical sectioning for 3D reconstruction, linear and spectral unmixing of overlapping emission spectra. It can acquire brightfield and DIC images with the transmission detector.
LSM780FLIM inverse CRTD.jpg


[edit] Directions

CRTD logo.PNG
Imaging@Biotec.jpgImaging@BIOTEC/CRTD (CRTD, -1.124)

[edit] Booking

https://techpool.biotec.tu-dresden.de/schedule/schedule.php?scheduleid=sc142df4c59eef5c

[edit] Details

microscope Zeiss - Axio Observer, Inverted stand, -
objectives
Zeiss Plan-Apochromat 10x 0.45
Zeiss Plan-Apochromat 20x 0.8
Zeiss C-Apochromat 40x 1.2 W
Zeiss alpha Plan-Apochromat 63x 1.46 Oil
illumination
Laser Diode 440 nm (pulsed)
Laser Diode 475 nm (pulsed)
Laser Argon Multiline 458, 488, 514 nm
Laser DPSS 561 nm
Laser HeNe 633 nm
Fluorescence (Metal Halide, HXP, 120W)
Transmitted Light (Halogen)
detection 32 PMT channels (GaAsP)

2 PMTs
transmission detector

reflectors Zeiss set 49: DAPI

Zeiss set 38: GFP
Zeiss set 47: CFP
Zeiss set 46: YFP
Zeiss set 43: Cy3

features spectral scan, FLIM dual channel unit from B&H
software ZEN black 2011
incubation Cage incubator (T+CO2+Humidity)
links
  • [ beam path]
  • [ advanced system check]
inv.nr. 84844



Personal tools