− | + | =1 slide per point= | |
+ | # What is a Microscope - Provdides Magnification and more importantly Resolution. | ||
+ | ## Basic Ray Optics of a Lens. | ||
+ | ## refraction | ||
+ | ## Conjugate planes | ||
+ | ###Single Lens has 2 focal planes FFP and BFP | ||
+ | ### little microscope | ||
+ | ### What is confocal | ||
+ | # Resolution | ||
+ | ## optical resolution - Point Spread Function / Airy Disk | ||
+ | ##Pixel Spacing (size?) Physical CCD dexels vs Picture Elements vs point scanning | ||
+ | ## Numerical Aperture vs Magnification : Abbe/Rayleigh Resolution d = lambda / 2NA | ||
# What is contrast? (No light = no image; no contrast = no resolution) | # What is contrast? (No light = no image; no contrast = no resolution) | ||
− | # Fluorescence and Stokes Shift | + | ## Fluorescence and Stokes Shift |
− | # | + | ### Spectrum databases / viewers for planning expt. |
− | # | + | # Detectors: CCD vs. PMT Widefield vs point detection |
− | # | + | ## Digitization |
− | # Coverslip thickness is part of the objective design (#1.5 0.17 mm +- 0.01) | + | ## Detector Saturation |
− | # | + | # Objective language / reading |
− | # | + | ## Coverslip thickness is part of the objective design (#1.5 0.17 mm +- 0.01) |
+ | ## Lens Immersion media | ||
+ | ## old oil, wrong oil, wrong collar setting | ||
+ | ## Lens cleaning | ||
# safety ; mercury lamps, lasers (jewelry, interlocks) | # safety ; mercury lamps, lasers (jewelry, interlocks) | ||
+ | # Project Planning / Workflow | ||
+ | |||
+ | # Admin intro | ||
+ | ## New User 30 min [[Checklist_for_introducing_new_users_to_the_MPI-CBG_LMF/IPF_facility|new user checklist]] |
Revision as of 11:41, 20 September 2010
1 slide per point
- What is a Microscope - Provdides Magnification and more importantly Resolution.
- Basic Ray Optics of a Lens.
- refraction
- Conjugate planes
- Single Lens has 2 focal planes FFP and BFP
- little microscope
- What is confocal
- Resolution
- optical resolution - Point Spread Function / Airy Disk
- Pixel Spacing (size?) Physical CCD dexels vs Picture Elements vs point scanning
- Numerical Aperture vs Magnification : Abbe/Rayleigh Resolution d = lambda / 2NA
- What is contrast? (No light = no image; no contrast = no resolution)
- Fluorescence and Stokes Shift
- Spectrum databases / viewers for planning expt.
- Fluorescence and Stokes Shift
- Detectors: CCD vs. PMT Widefield vs point detection
- Digitization
- Detector Saturation
- Objective language / reading
- Coverslip thickness is part of the objective design (#1.5 0.17 mm +- 0.01)
- Lens Immersion media
- old oil, wrong oil, wrong collar setting
- Lens cleaning
- safety ; mercury lamps, lasers (jewelry, interlocks)
- Project Planning / Workflow
- Admin intro
- New User 30 min new user checklist