Live Cell/TIRF AF6000, BIOTEC

From BioDIP
(Difference between revisions)
Jump to: navigation, search
Line 10: Line 10:
 
| description          = Our Leica AFLX6000 TIRF is designed for observation of LiveCell systems (incubator) and phenomenons at the interface between the cells and their substrate. The laser lines are well distributed over the spectrum and especially good for common dye combinations. A system of external emission filters wheel allows extremely fast acquisition in combination with an EMCCD for detection of low signal.
 
| description          = Our Leica AFLX6000 TIRF is designed for observation of LiveCell systems (incubator) and phenomenons at the interface between the cells and their substrate. The laser lines are well distributed over the spectrum and especially good for common dye combinations. A system of external emission filters wheel allows extremely fast acquisition in combination with an EMCCD for detection of low signal.
 
| microscope          = inverted stand, motorized XY stage, Super Z-stage, fluorescence, transmitted light with automatic DIC, TIRF
 
| microscope          = inverted stand, motorized XY stage, Super Z-stage, fluorescence, transmitted light with automatic DIC, TIRF
| excitation          = laser (nm): 405, 488, 561, 635
+
| illumination        = laser (nm): 405, 488, 561, 635
 
| detection            = Andor EMCCD (512*512, 16µm pixels), Leica DFC (1392*1040, 6,45µm pixels), reflectors for fluorescence and TIRF, external emission filter wheel for rapid acquisition with Andor EMCCD
 
| detection            = Andor EMCCD (512*512, 16µm pixels), Leica DFC (1392*1040, 6,45µm pixels), reflectors for fluorescence and TIRF, external emission filter wheel for rapid acquisition with Andor EMCCD
 
| features            = sequential imaging, Z stacks, time-series, advanced time-series, multiple position imaging, fast acquisition (with Andor EMCCD)
 
| features            = sequential imaging, Z stacks, time-series, advanced time-series, multiple position imaging, fast acquisition (with Andor EMCCD)
 
}}
 
}}

Revision as of 15:23, 16 June 2008

Suitable for text.
[[image:|250px]]


Directions

[[image:|150px|text-bottom|right]]

[[image:|100px]] Imaging@Biotec"Imaging@Biotec" is not in the list of possible values (DZNE - Imaging Platform, EM- and Histo-Facility CRTD / BIOTEC, Image Processing@BIOTEC, Imaging@BIOTEC/CRTD, MPI-CBG LMF, MPI-CBG LMF - Quantitative Image Analysis Unit, MPI-CBG TDS, MTZ Imaging, MPI-CBG EM, BioDIP) for this property. ("Biotec" is not in the list of possible values (BIOTEC, CRTD, DZNE, MTZ, MPI-CBG) for this property., 226)

Booking

https://techpool.biotec.tu-dresden.de/schedule/schedule.php?scheduleid=sc142df4c59eef5c

Details

microscope , stand, inverted stand, motorized XY stage, Super Z-stage, fluorescence, transmitted light with automatic DIC, TIRF
objectives
illumination
detection Andor EMCCD (512*512, 16µm pixels), Leica DFC (1392*1040, 6,45µm pixels), reflectors for fluorescence and TIRF, external emission filter wheel for rapid acquisition with Andor EMCCD