MTZ01 - Zeiss LSM 510
From BioDIP
(Difference between revisions)
Line 13: | Line 13: | ||
|stand=Inverted | |stand=Inverted | ||
|microscope=manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | |microscope=manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|obj1=Zeiss EC Plan-Neofluar 10x 0.3 | |obj1=Zeiss EC Plan-Neofluar 10x 0.3 | ||
|obj2=Zeiss LCI Plan-Neofluar 25x 0.8 Imm Corr | |obj2=Zeiss LCI Plan-Neofluar 25x 0.8 Imm Corr | ||
Line 30: | Line 21: | ||
|obj7=- | |obj7=- | ||
|obj8=- | |obj8=- | ||
+ | |ill1=Transmitted Light (Halogen) | ||
+ | |ill2=Fluorescence (HBO) | ||
+ | |ill3=Laser Diode 405 nm | ||
+ | |ill4=Laser Argon Multiline 458, 477, 488, 514 nm | ||
+ | |ill5=Laser DPSS 561 nm | ||
+ | |ill6=Laser HeNe 633 nm | ||
+ | |ill7=- | ||
+ | |ill8=- | ||
+ | |detection=point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector | ||
+ | |reflectors=EX 350/50, EM 460/50<br>EX 472/30, EM 520/35<br>EX 546/12, EM LP590 | ||
+ | |features=simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation | ||
+ | |incubation=- | ||
+ | |link1=http://spreadsheets.google.com/pub?key=pFf3a5iBejjAwSkUV9oO6fw | ||
+ | |link2=https://spreadsheets.google.com/pub?key=pMZJXCgd5HNumbQenUfeIeA | ||
+ | |inv=- | ||
+ | |objectives=10x/0.3<br>25x/0.8 ImmCorr<br>40x/1.3 Oil<br>63x/1.4 Oil Apo<br>63x/1.2 W Apo | ||
+ | |illumination=Halogen<br>HBO<br>405 nm Diode laser<br>458, 488, 514 nm Argon laser<br>561 nm DPSS laser<br>633 nm HeNe laser | ||
}} | }} |
Revision as of 14:57, 4 September 2009
Directions
[[image:|150px|text-bottom|right]]
Booking
https://cgc.med.tu-dresden.de/phpScheduleIt
Details
microscope | , Inverted stand, manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | ||
objectives | |||
illumination | |||
detection | point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector | ||
reflectors | EX 350/50, EM 460/50 EX 472/30, EM 520/35 EX 546/12, EM LP590 | ||
features | simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation | ||
software | |||
incubation | - | ||
links |
| ||
inv.nr. | - |