MTZ01 - Zeiss LSM 510

From BioDIP
(Difference between revisions)
Jump to: navigation, search
(category)
Line 9: Line 9:
 
| description          = Our Zeiss LSM 510 is designed for routine work and dedicated for high resolution imaging in XYZ. The laser lines are well distributed over the spectrum and especially good for common dye combinations. Due to the conventional setup, it's straight forward to work with.
 
| description          = Our Zeiss LSM 510 is designed for routine work and dedicated for high resolution imaging in XYZ. The laser lines are well distributed over the spectrum and especially good for common dye combinations. Due to the conventional setup, it's straight forward to work with.
 
| microscope          = inverted stand, manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC
 
| microscope          = inverted stand, manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC
 +
| objectives          = 10x/0.3<br>25x/0.8 ImmCorr<br>40x/1.3 Oil<br>63x/1.4 Oil Apo<br>63x/1.2 W Apo
 
| excitation          = laser (nm): 405, 458, 488, 514, 561, 633
 
| excitation          = laser (nm): 405, 458, 488, 514, 561, 633
 
| detection            = point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector
 
| detection            = point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector
 +
| reflectors          = DAPI BP<br>GFP BP<br>RFP LP
 
| features            = simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation
 
| features            = simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation
 
}}
 
}}

Revision as of 10:17, 16 June 2008

Suitable for text.
MTZ01.jpg


Directions

[[image:|150px|text-bottom|right]]

[[image:|100px]] MTZ Imaging (MTZ, B20.001B)

Booking

https://cgc.med.tu-dresden.de/phpScheduleIt

Details

microscope , stand, inverted stand, manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC
objectives
illumination
detection point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector
reflectors DAPI BP
GFP BP
RFP LP
features simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation
software
incubation
links
  • [ manual]
  • [ laser power values]
  • [ beam path]
  • [ advanced system check]
inv.nr.



[[Category:{{{type}}}]]






Personal tools