MTZ01 - Zeiss LSM 510

From BioDIP
(Difference between revisions)
Jump to: navigation, search
Line 12: Line 12:
 
| objectives          = 10x/0.3<br>25x/0.8 ImmCorr<br>40x/1.3 Oil<br>63x/1.4 Oil Apo<br>63x/1.2 W Apo
 
| objectives          = 10x/0.3<br>25x/0.8 ImmCorr<br>40x/1.3 Oil<br>63x/1.4 Oil Apo<br>63x/1.2 W Apo
 
| excitation          = HBO<br>405nm Diode laser<br>458, 488, 514nm Argon laser<br>561nm DPSS laser<br>633nm HeNe laser
 
| excitation          = HBO<br>405nm Diode laser<br>458, 488, 514nm Argon laser<br>561nm DPSS laser<br>633nm HeNe laser
| detection            = point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector
+
| detection            = point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector<br>[http://tu-dresden.de/die_tu_dresden/fakultaeten/medizinische_fakultaet/mtz/mtzImaging/systems/01_zeiss_lsm_510/01_zeiss_lsm_510_filterconfig.pdf scan-head filter configuration]
 
| reflectors          = DAPI (EX 350/50, EM 460/50)<br>GFP (EX 472/30, EM 520/35)<br>RFP (EX 546/12, EM LP590)
 
| reflectors          = DAPI (EX 350/50, EM 460/50)<br>GFP (EX 472/30, EM 520/35)<br>RFP (EX 546/12, EM LP590)
 
| features            = simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation
 
| features            = simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation
 
}}
 
}}

Revision as of 11:59, 16 June 2008

Suitable for text.
MTZ01.jpg


Directions

[[image:|150px|text-bottom|right]]

[[image:|100px]] MTZ Imaging (MTZ, B20.001B)

Booking

https://cgc.med.tu-dresden.de/phpScheduleIt

Details

microscope , stand, inverted stand, manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC
objectives
illumination
detection [[detection::point scanner, 3 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, emission filters for detection range selection, pinhole for each detector
scan-head filter configuration]]
reflectors DAPI (EX 350/50, EM 460/50)
GFP (EX 472/30, EM 520/35)
RFP (EX 546/12, EM LP590)
features simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation