MTZ02 - Leica TCS SP5

From BioDIP
(Difference between revisions)
Jump to: navigation, search
m
Line 8: Line 8:
 
| building            = MTZ
 
| building            = MTZ
 
| room                = B20.001C
 
| room                = B20.001C
| description          = Our Leica TCS SP5 is specialized for Life Cell Imaging, FRET and FRAP. It's laser equipment makes it suitable for i.e. GFP+mCherry and CFP+YFP. Modules for time-series and bleaching experiments allow to run also more complex experiments. Beside that, one can also perform high resolution scans with fixed and embedded samples. The spectral detection system offers flexibility in the combination of dyes. Motorized stage and DIC optics offer the possibility to perform semi-automated microscopy.
+
| description          = Our Leica TCS SP5 is specialized for Life Cell Imaging, FRET and FRAP. It's laser equipment makes it suitable for i.e. GFP+mCherry and CFP+YFP. Modules for time-series and bleaching experiments allow to run also more complex experiments, but one can also perform high resolution scans with fixed and embedded samples. The spectral detection system offers flexibility in the combination of dyes. Motorized stage and DIC optics offer the possibility to perform semi-automated microscopy.
 
| microscope          = inverted stand, motorized XY stage, motorized Z-drive, fast Z-stage, fluorescence, transmitted light with motorized DIC
 
| microscope          = inverted stand, motorized XY stage, motorized Z-drive, fast Z-stage, fluorescence, transmitted light with motorized DIC
 
| objectives          = 10x/0.3<br>25x/0.8 ImmCorr<br>40x/1.3 Oil<br>63x/1.4 Oil Apo<br>63x/1.2 W Apo
 
| objectives          = 10x/0.3<br>25x/0.8 ImmCorr<br>40x/1.3 Oil<br>63x/1.4 Oil Apo<br>63x/1.2 W Apo

Revision as of 12:10, 16 June 2008

Suitable for text.
MTZ02.jpg


Directions

[[image:|150px|text-bottom|right]]

[[image:|100px]] MTZ Imaging (MTZ, B20.001C)

Booking

https://cgc.med.tu-dresden.de/phpScheduleIt

Details

microscope , stand, inverted stand, motorized XY stage, motorized Z-drive, fast Z-stage, fluorescence, transmitted light with motorized DIC
objectives
illumination
detection point scanner, 3 confocal PMTs, T-PMT, AOBS for excitation/emission splitting, prism and spectral sliders for detection range selection, central pinhole
reflectors DAPI (EX 360/40, EM LP425)
GFP (EX 470/40, EM LP515)
RFP (EX 538/45, EM LP590)
features simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, fast XZ-scans, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation, tile scan, mosaic scan, lambda scan, FRET macro, FRAP macro
software
incubation heating chamber
links
  • [ manual]
  • [ laser power values]
  • [ beam path]
  • [ advanced system check]
inv.nr.



[[Category:{{{type}}}]]