SD1 - Andor Spinning Disc
From BioDIP
(Difference between revisions)
Line 15: | Line 15: | ||
| illumination = Halogen<br>HBO<br>488 nm solid-state laser Coherent Sapphire<br>561 nm solid-state laser Cobolt Jive | | illumination = Halogen<br>HBO<br>488 nm solid-state laser Coherent Sapphire<br>561 nm solid-state laser Cobolt Jive | ||
| detection = Spinning disc scan head Yokogawa CSU10: dichromatic mirror: [http://www.semrock.com/Catalog/Detail.aspx?FilterPartID=855&CategoryID=82 T-405/488/568/647]<br> physical pinhole radius: 24um, physical pinhole spacing: 240um; back-projected pinhole radius: 0.15um, back-projected pinhole spacing: 1.5um (with 100x objective, 1.6x optovar)<br>Andor iXon EM+ DU-897 BV back illuminated EMCCD; pixel size of EMCCD chip: 16um<br>image pixel size: with 100x objective: 0.16um; 100x obj. and 1.6x optovar: 0.1um; 60x obj.: 0.267um; 60x obj. and 1.6x opt.: 0.167um | | detection = Spinning disc scan head Yokogawa CSU10: dichromatic mirror: [http://www.semrock.com/Catalog/Detail.aspx?FilterPartID=855&CategoryID=82 T-405/488/568/647]<br> physical pinhole radius: 24um, physical pinhole spacing: 240um; back-projected pinhole radius: 0.15um, back-projected pinhole spacing: 1.5um (with 100x objective, 1.6x optovar)<br>Andor iXon EM+ DU-897 BV back illuminated EMCCD; pixel size of EMCCD chip: 16um<br>image pixel size: with 100x objective: 0.16um; 100x obj. and 1.6x optovar: 0.1um; 60x obj.: 0.267um; 60x obj. and 1.6x opt.: 0.167um | ||
− | | reflectors = Optical Insight DualView image splitter: <br>HC 520/35; BS 565; HC 628/40<br>Sutter filter wheel: <br>position 0: 624/40, 1: open, 2: 525/30, 3: razor edge 568LP, 4: dual emitter: 512/23+630/91, 5: razor edge 488LP, 6: old CSU dual emitter: 525/30 + 650/?, 7: blocked, 8: blocked, 9: 716/40<br> microscope filter turret:<br> position 1: GFP cube, 2: RFP cube, 3: dual GFP + RFP cube, 4: | + | | reflectors = Optical Insight DualView image splitter: <br>HC 520/35; BS 565; HC 628/40<br>Sutter filter wheel: <br>position 0: 624/40, 1: open, 2: 525/30, 3: razor edge 568LP, 4: dual emitter: 512/23+630/91, 5: razor edge 488LP, 6: old CSU dual emitter: 525/30 + 650/?, 7: blocked, 8: blocked, 9: 716/40<br> microscope filter turret:<br> position 1: GFP cube, 2: RFP cube, 3: dual GFP + RFP cube, 4: DAPI cube, 5: empty, 6: DIC analyzer |
| features = | | features = | ||
| incubation = stage incubator | | incubation = stage incubator |
Revision as of 10:04, 30 January 2009
Directions
[[image:|150px|text-bottom|right]]
Booking
https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py
Details
microscope | , inverted, manual, 1.6x optovar stand, Olympus IX71, fast piezo z-drive for objective | ||
objectives |
| ||
illumination |
| ||
detection | [[detection::Spinning disc scan head Yokogawa CSU10: dichromatic mirror: T-405/488/568/647 physical pinhole radius: 24um, physical pinhole spacing: 240um; back-projected pinhole radius: 0.15um, back-projected pinhole spacing: 1.5um (with 100x objective, 1.6x optovar) Andor iXon EM+ DU-897 BV back illuminated EMCCD; pixel size of EMCCD chip: 16um image pixel size: with 100x objective: 0.16um; 100x obj. and 1.6x optovar: 0.1um; 60x obj.: 0.267um; 60x obj. and 1.6x opt.: 0.167um]] | ||
reflectors | Optical Insight DualView image splitter: HC 520/35; BS 565; HC 628/40 Sutter filter wheel: position 0: 624/40, 1: open, 2: 525/30, 3: razor edge 568LP, 4: dual emitter: 512/23+630/91, 5: razor edge 488LP, 6: old CSU dual emitter: 525/30 + 650/?, 7: blocked, 8: blocked, 9: 716/40 microscope filter turret: position 1: GFP cube, 2: RFP cube, 3: dual GFP + RFP cube, 4: DAPI cube, 5: empty, 6: DIC analyzer | ||
features | |||
software | |||
incubation | stage incubator | ||
links |
| ||
inv.nr. |
[[Category:{{{type}}}]]