SD1 - Andor Spinning Disc

From BioDIP
(Difference between revisions)
Jump to: navigation, search
Line 3: Line 3:
 
| system-name          = Andor Spinning Disc
 
| system-name          = Andor Spinning Disc
 
| category            = Real-Time Confocal
 
| category            = Real-Time Confocal
| stand                = inverted, manual, 1.6x optovar
+
| stand                = inverted
 
| image                = MPI19.jpg
 
| image                = MPI19.jpg
 
| facility            = MPI-CBG LMF
 
| facility            = MPI-CBG LMF
Line 11: Line 11:
 
| description          = fast, "real-time" confocal imaging
 
| description          = fast, "real-time" confocal imaging
 
| applications        = confocal imaging of EGFP and mCherry with high temporal and spatial resolution.
 
| applications        = confocal imaging of EGFP and mCherry with high temporal and spatial resolution.
| microscope          = Olympus IX71, fast piezo z-drive for objective
+
| microscope          = manual Olympus IX71, 1.6x OptoVar, fast piezo z-drive for objective
 
| objectives          = 10x / 0.30  Plan-Neofluar<br>60x / 1.20 W  UPlanSApo<br>100x / 1.40 Oil  UPlanSApo
 
| objectives          = 10x / 0.30  Plan-Neofluar<br>60x / 1.20 W  UPlanSApo<br>100x / 1.40 Oil  UPlanSApo
 
| illumination        = Halogen<br>HBO<br>488 nm solid-state laser Coherent Sapphire, 75mW<br>561 nm solid-state laser Cobolt Jive, 40mW
 
| illumination        = Halogen<br>HBO<br>488 nm solid-state laser Coherent Sapphire, 75mW<br>561 nm solid-state laser Cobolt Jive, 40mW

Revision as of 16:16, 10 August 2009

Suitable for confocal imaging of EGFP and mCherry with high temporal and spatial resolution..
MPI19.jpg


Directions

[[image:|150px|text-bottom|right]]

[[image:|100px]] MPI-CBG LMF (MPI-CBG, 038B)

Booking

https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py

Details

microscope , inverted stand, manual Olympus IX71, 1.6x OptoVar, fast piezo z-drive for objective
objectives
illumination
detection [[detection::Spinning disc scan head Yokogawa CSU10: dichromatic mirror: T-405/488/568/647
physical pinhole radius: 24um, physical pinhole spacing: 240um; back-projected pinhole radius: 0.15um, back-projected pinhole spacing: 1.5um (with 100x objective, 1.6x optovar)
Andor iXon EM+ DU-897 BV back illuminated EMCCD; pixel size of EMCCD chip: 16um
image pixel size (measured): with 100x objective: 0.178um; 100x obj. and 1.6x optovar: 0.111um; 60x obj.: 0.288um; 60x obj. and 1.6x opt.: 0.181um]]
reflectors Optical Insight DualView image splitter:
HC 520/35; BS 565; HC 628/40
Sutter filter wheel:
position 0: 624/40, 1: open, 2: 525/30, 3: razor edge 568LP, 4: dual emitter: 512/23+630/91, 5: razor edge 488LP, 6: old CSU dual emitter: 525/30 + 650/?, 7: blocked, 8: blocked, 9: 716/40
microscope filter turret:
position 1: GFP cube, 2: RFP cube, 3: dual GFP + RFP cube, 4: DAPI cube, 5: empty, 6: DIC analyzer
features
software
incubation stage incubator
links
  • [ manual]
  • [LPM laser power values]
  • [- beam path]
  • [ advanced system check]
inv.nr.



[[Category:{{{type}}}]]






Personal tools