|microscope=manual Olympus IX71, 1.6x OptoVar, fast piezo z-drive for objective | |microscope=manual Olympus IX71, 1.6x OptoVar, fast piezo z-drive for objective | ||
|obj1=Zeiss EC Plan-Neofluar 10x 0.3 | |obj1=Zeiss EC Plan-Neofluar 10x 0.3 | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|ill1=Transmitted Light (Halogen) | |ill1=Transmitted Light (Halogen) | ||
|ill2=Fluorescence (HBO) | |ill2=Fluorescence (HBO) | ||
|ill3=Laser DPSS 488 nm | |ill3=Laser DPSS 488 nm | ||
|ill4=Laser DPSS 561 nm | |ill4=Laser DPSS 561 nm | ||
− | |||
− | |||
− | |||
− | |||
|detection=Spinning disc scan head Yokogawa CSU10: dichromatic mirror: [http://www.semrock.com/Catalog/Detail.aspx?FilterPartID=855&CategoryID=82 T-405/488/568/647]<br> physical pinhole radius: 24um, physical pinhole spacing: 240um; back-projected pinhole radius: 0.15um, back-projected pinhole spacing: 1.5um (with 100x objective, 1.6x optovar)<br>Andor iXon EM+ DU-897 BV back illuminated EMCCD; pixel size of EMCCD chip: 16um<br>image pixel size (measured): with 100x objective: 0.178um; 100x obj. and 1.6x optovar: 0.111um; 60x obj.: 0.288um; 60x obj. and 1.6x opt.: 0.181um | |detection=Spinning disc scan head Yokogawa CSU10: dichromatic mirror: [http://www.semrock.com/Catalog/Detail.aspx?FilterPartID=855&CategoryID=82 T-405/488/568/647]<br> physical pinhole radius: 24um, physical pinhole spacing: 240um; back-projected pinhole radius: 0.15um, back-projected pinhole spacing: 1.5um (with 100x objective, 1.6x optovar)<br>Andor iXon EM+ DU-897 BV back illuminated EMCCD; pixel size of EMCCD chip: 16um<br>image pixel size (measured): with 100x objective: 0.178um; 100x obj. and 1.6x optovar: 0.111um; 60x obj.: 0.288um; 60x obj. and 1.6x opt.: 0.181um | ||
|reflectors=Optical Insight DualView image splitter: <br>HC 520/35; BS 565; HC 628/40<br>Sutter filter wheel: <br>position 0: 624/40, 1: open, 2: 525/30, 3: razor edge 568LP, 4: dual emitter: 512/23+630/91, 5: razor edge 488LP, 6: old CSU dual emitter: 525/30 + 650/?, 7: blocked, 8: blocked, 9: 716/40<br> microscope filter turret:<br> position 1: GFP cube, 2: RFP cube, 3: dual GFP + RFP cube, 4: DAPI cube, 5: empty, 6: DIC analyzer | |reflectors=Optical Insight DualView image splitter: <br>HC 520/35; BS 565; HC 628/40<br>Sutter filter wheel: <br>position 0: 624/40, 1: open, 2: 525/30, 3: razor edge 568LP, 4: dual emitter: 512/23+630/91, 5: razor edge 488LP, 6: old CSU dual emitter: 525/30 + 650/?, 7: blocked, 8: blocked, 9: 716/40<br> microscope filter turret:<br> position 1: GFP cube, 2: RFP cube, 3: dual GFP + RFP cube, 4: DAPI cube, 5: empty, 6: DIC analyzer |
Revision as of 17:39, 16 September 2009
Directions
[[image:|150px|text-bottom|right]]
Booking
https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py
Details
microscope | , Inverted stand, manual Olympus IX71, 1.6x OptoVar, fast piezo z-drive for objective | ||
objectives | |||
illumination | |||
detection | [[detection::Spinning disc scan head Yokogawa CSU10: dichromatic mirror: T-405/488/568/647 physical pinhole radius: 24um, physical pinhole spacing: 240um; back-projected pinhole radius: 0.15um, back-projected pinhole spacing: 1.5um (with 100x objective, 1.6x optovar) Andor iXon EM+ DU-897 BV back illuminated EMCCD; pixel size of EMCCD chip: 16um image pixel size (measured): with 100x objective: 0.178um; 100x obj. and 1.6x optovar: 0.111um; 60x obj.: 0.288um; 60x obj. and 1.6x opt.: 0.181um]] | ||
reflectors | Optical Insight DualView image splitter: HC 520/35; BS 565; HC 628/40 Sutter filter wheel: position 0: 624/40, 1: open, 2: 525/30, 3: razor edge 568LP, 4: dual emitter: 512/23+630/91, 5: razor edge 488LP, 6: old CSU dual emitter: 525/30 + 650/?, 7: blocked, 8: blocked, 9: 716/40 microscope filter turret: position 1: GFP cube, 2: RFP cube, 3: dual GFP + RFP cube, 4: DAPI cube, 5: empty, 6: DIC analyzer | ||
features | - | ||
software | |||
incubation | stage incubator (T) + objective heater | ||
links |
| ||