SD2 - Andor Spinning Disc FRAPPA
From BioDIP
(Difference between revisions)
(adding 20x and 100x objwectives, dual camera port and magnification changes) |
(added Clara and dual camera port) |
||
Line 27: | Line 27: | ||
|ill6=Laser DPSS 640 nm | |ill6=Laser DPSS 640 nm | ||
|ill7=Laser Diode 405 nm (pulsed) | |ill7=Laser Diode 405 nm (pulsed) | ||
− | |detection=Spinning disc scan head Yokogawa CSU-X1; pinhole size: 24um, pinhole spacing: 240um; back-projected pinhole size: 0.4um, back-projected pinhole spacing: 4um (with 60x objective, 1x optovar)<br>Andor iXon EM+ DU-897 BV back illuminated EMCCD; pixel size of EMCCD chip: 16um<br>note there are two additional lenses in the optical path: 1.0x before and 2.067x (was 1.9x before additionof dual camera switch) after the CSU<br>image pixel size (calculated): with 100x: 0.077um; with 60x objective: 0.129 (was 0.14um); 60x obj. and 2.0x optovar: 0.0645um (was 0.07um); 40x obj.: 0.194um (was 0.21um); 40x obj. and 2.0x opt.: 0.0967um (was 0.11um) <br> | + | |detection=Spinning disc scan head Yokogawa CSU-X1; pinhole size: 24um, pinhole spacing: 240um; back-projected pinhole size: 0.4um, back-projected pinhole spacing: 4um (with 60x objective, 1x optovar)<br>Andor Dual camera port with two cameras: <br>Andor iXon EM+ DU-897 BV back illuminated EMCCD; pixel size of EMCCD chip: 16um<br>Andor Clara cooled interline CCD; pixel size of chip: 6.45um<br>note there are two additional lenses in the optical path: 1.0x before and 2.067x (was 1.9x before additionof dual camera switch) after the CSU<br>image pixel size (calculated): with 100x: 0.077um; with 60x objective: 0.129 (was 0.14um); 60x obj. and 2.0x optovar: 0.0645um (was 0.07um); 40x obj.: 0.194um (was 0.21um); 40x obj. and 2.0x opt.: 0.0967um (was 0.11um) <br> |
|reflectors=Optical Insight DualView image splitter: <br> insert with HC 520/35; BS 595 dcxr; HC 628/40 for GFP/RFP splitting<br>insert with T565 lpxr DC and empty EM position<br>insert for CFP/YFP splitting<br>Sutter filter wheel: <br>position 0: 440/521/607/700 Quadband, 1: razor edge 488LP, 2: blocked, 3: razor edge 568LP, 4: Edge Basic longpass 635 LP, 5: BrightLine 445/45, 6: open, 7: polarizer for DIC, 8: 525/30, 9: BrightLine HC 607/36<br> microscope filter turret:<br> position 1: empty, 2: DIC, 3: tripple DAPI + GFP + RFP cube, 4: GFP, 5: RFP, 6: DAPI cube (X 345/10; D 380LP; M 445/40) | |reflectors=Optical Insight DualView image splitter: <br> insert with HC 520/35; BS 595 dcxr; HC 628/40 for GFP/RFP splitting<br>insert with T565 lpxr DC and empty EM position<br>insert for CFP/YFP splitting<br>Sutter filter wheel: <br>position 0: 440/521/607/700 Quadband, 1: razor edge 488LP, 2: blocked, 3: razor edge 568LP, 4: Edge Basic longpass 635 LP, 5: BrightLine 445/45, 6: open, 7: polarizer for DIC, 8: 525/30, 9: BrightLine HC 607/36<br> microscope filter turret:<br> position 1: empty, 2: DIC, 3: tripple DAPI + GFP + RFP cube, 4: GFP, 5: RFP, 6: DAPI cube (X 345/10; D 380LP; M 445/40) | ||
|features=Andor FRAPPA<br>405nm pulsed diode laser from PicoQuant | |features=Andor FRAPPA<br>405nm pulsed diode laser from PicoQuant |
Revision as of 21:52, 1 July 2010
Directions
[[image:|150px|text-bottom|right]]
Booking
https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py
Details
microscope | Olympus - IX81, Inverted stand, motorized with ZDC (hardware autofocus), 2x Optovar, Prior NanoScanZ, Prior ProScanIII xy scanning stage | ||
objectives | |||
illumination | |||
detection | Spinning disc scan head Yokogawa CSU-X1; pinhole size: 24um, pinhole spacing: 240um; back-projected pinhole size: 0.4um, back-projected pinhole spacing: 4um (with 60x objective, 1x optovar) Andor Dual camera port with two cameras: Andor iXon EM+ DU-897 BV back illuminated EMCCD; pixel size of EMCCD chip: 16um Andor Clara cooled interline CCD; pixel size of chip: 6.45um note there are two additional lenses in the optical path: 1.0x before and 2.067x (was 1.9x before additionof dual camera switch) after the CSU image pixel size (calculated): with 100x: 0.077um; with 60x objective: 0.129 (was 0.14um); 60x obj. and 2.0x optovar: 0.0645um (was 0.07um); 40x obj.: 0.194um (was 0.21um); 40x obj. and 2.0x opt.: 0.0967um (was 0.11um) | ||
reflectors | Optical Insight DualView image splitter: insert with HC 520/35; BS 595 dcxr; HC 628/40 for GFP/RFP splitting insert with T565 lpxr DC and empty EM position insert for CFP/YFP splitting Sutter filter wheel: position 0: 440/521/607/700 Quadband, 1: razor edge 488LP, 2: blocked, 3: razor edge 568LP, 4: Edge Basic longpass 635 LP, 5: BrightLine 445/45, 6: open, 7: polarizer for DIC, 8: 525/30, 9: BrightLine HC 607/36 microscope filter turret: position 1: empty, 2: DIC, 3: tripple DAPI + GFP + RFP cube, 4: GFP, 5: RFP, 6: DAPI cube (X 345/10; D 380LP; M 445/40) | ||
features | Andor FRAPPA 405nm pulsed diode laser from PicoQuant"Andor FRAPPA<br />405nm pulsed diode laser from PicoQuant" cannot be used as a page name in this wiki. | ||
software | [[software::iQ 1.10.2 user guide]] | ||
incubation | Stage incubator (T) + objective heater | ||
links |
| ||
inv.nr. | 0 |