SP5 I, upright, BIOTEC

From BioDIP
(Difference between revisions)
Jump to: navigation, search
Line 10: Line 10:
 
| description          = Our Leica SP5 I is designed for routine work and dedicated for high resolution imaging in XYZ. The upright confoguration and the dipping lenses make it optimal for embryo development studies. The laser lines are well distributed over the spectrum and especially good for common dye combinations. Due to the conventional setup, it's straight forward to work with.
 
| description          = Our Leica SP5 I is designed for routine work and dedicated for high resolution imaging in XYZ. The upright confoguration and the dipping lenses make it optimal for embryo development studies. The laser lines are well distributed over the spectrum and especially good for common dye combinations. Due to the conventional setup, it's straight forward to work with.
 
| microscope          = upright stand, motorized XYZ stage, Z-piezo stage, fluorescence, transmitted light with automatic DIC
 
| microscope          = upright stand, motorized XYZ stage, Z-piezo stage, fluorescence, transmitted light with automatic DIC
 +
| objectives          =
 
| excitation          = laser (nm): 405, 458, 476, 488, 496, 514, 561, 633
 
| excitation          = laser (nm): 405, 458, 476, 488, 496, 514, 561, 633
 
| detection            = point scanner, 5 confocal PMTs, T-PMT, AOBS for excitation/emission splitting, SP detector for detection range selection, common pinhole
 
| detection            = point scanner, 5 confocal PMTs, T-PMT, AOBS for excitation/emission splitting, SP detector for detection range selection, common pinhole
 +
| reflectors          =
 
| features            = simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, multi-position imaging, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation
 
| features            = simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, multi-position imaging, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation
 +
| incubation          = none
 
}}
 
}}

Revision as of 12:20, 16 June 2008

Suitable for text.
[[image:|250px]]


Directions

[[image:|150px|text-bottom|right]]

[[image:|100px]] Imaging@Biotec"Imaging@Biotec" is not in the list of possible values (DZNE - Imaging Platform, EM- and Histo-Facility CRTD / BIOTEC, Image Processing@BIOTEC, Imaging@BIOTEC/CRTD, MPI-CBG LMF, MPI-CBG LMF - Quantitative Image Analysis Unit, MPI-CBG TDS, MTZ Imaging, MPI-CBG EM, BioDIP) for this property. ("Biotec" is not in the list of possible values (BIOTEC, CRTD, DZNE, MTZ, MPI-CBG) for this property., 220)

Booking

https://techpool.biotec.tu-dresden.de/schedule/schedule.php?scheduleid=sc142df4c59eef5c

Details

microscope , stand, upright stand, motorized XYZ stage, Z-piezo stage, fluorescence, transmitted light with automatic DIC
objectives
illumination
detection point scanner, 5 confocal PMTs, T-PMT, AOBS for excitation/emission splitting, SP detector for detection range selection, common pinhole
reflectors
features simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, multi-position imaging, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation
software
incubation none
links
  • [ manual]
  • [ laser power values]
  • [ beam path]
  • [ advanced system check]
inv.nr.