SP5 II, upright, CRTD
From BioDIP
(Difference between revisions)
Line 11: | Line 11: | ||
| microscope = upright stand, motorized XYZ stage, Z-piezo stage, fluorescence, transmitted light with automatic DIC, resonating scanner (optional) | | microscope = upright stand, motorized XYZ stage, Z-piezo stage, fluorescence, transmitted light with automatic DIC, resonating scanner (optional) | ||
| objectives = 10x/0.4 DIC<br>10x/0.3 W (Dipping)<br>20x/0.7 DIC<br>40x/1.25-0.75 Oil<br>40x/0.8 W (Dipping)<br>63x/0.9 W (Dipping)<br>63x/1.2 W Corr DIC | | objectives = 10x/0.4 DIC<br>10x/0.3 W (Dipping)<br>20x/0.7 DIC<br>40x/1.25-0.75 Oil<br>40x/0.8 W (Dipping)<br>63x/0.9 W (Dipping)<br>63x/1.2 W Corr DIC | ||
− | | | + | | illumination = HBO lamp<br>Halogen lamp<br>405nm diode laser<br>458, 476, 488, 496, 514nm argon laser<br>561nm DPSS laser<br>633nm HeNe |
| detection = point scanner, 5 confocal PMTs, T-PMT, AOBS for excitation/emission splitting, SP detector for detection range selection, common pinhole | | detection = point scanner, 5 confocal PMTs, T-PMT, AOBS for excitation/emission splitting, SP detector for detection range selection, common pinhole | ||
| reflectors = DAPI (A) : EX 360/40 ; BS 400 ; EM LP 425<br>FITC (I3) : EX 470/40 ; BS 510 ; EM LP 515<br>TRITC (N2.1) : EX 537/45 ; BS 580 ; EM LP 590 LP | | reflectors = DAPI (A) : EX 360/40 ; BS 400 ; EM LP 425<br>FITC (I3) : EX 470/40 ; BS 510 ; EM LP 515<br>TRITC (N2.1) : EX 537/45 ; BS 580 ; EM LP 590 LP |
Revision as of 15:23, 16 June 2008
Directions
[[image:|150px|text-bottom|right]]
Booking
https://techpool.biotec.tu-dresden.de/schedule/schedule.php?scheduleid=sc142df4c59eef5c
Details
microscope | , stand, upright stand, motorized XYZ stage, Z-piezo stage, fluorescence, transmitted light with automatic DIC, resonating scanner (optional) | ||
objectives |
| ||
illumination |
| ||
detection | point scanner, 5 confocal PMTs, T-PMT, AOBS for excitation/emission splitting, SP detector for detection range selection, common pinhole | ||
reflectors | DAPI (A) : EX 360/40 ; BS 400 ; EM LP 425 FITC (I3) : EX 470/40 ; BS 510 ; EM LP 515 TRITC (N2.1) : EX 537/45 ; BS 580 ; EM LP 590 LP | ||
features | simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, multi-position imaging, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation, FRAP, resonating scanner | ||
software | |||
incubation | Temperature control, CO2 control on requirement | ||
links |
| ||
inv.nr. |
[[Category:{{{type}}}]]