W4 - Zeiss Inverted CCD

From BioDIP
(Difference between revisions)
Jump to: navigation, search
m (mpi added)
Line 1: Line 1:
 
{{Equipment
 
{{Equipment
| system-number       = MPI10
+
|system-number=MPI10
| system-name         = Zeiss Inverted CCD
+
|system-name=Zeiss Inverted CCD
| category             = Wide-Field
+
|type=Microscope
| stand                = inverted
+
|category=Wide-Field
| image                = MPI10.jpg
+
|facility=MPI-CBG LMF
| facility             = MPI-CBG LMF
+
|building=MPI-CBG
| facility_image      = logo-lmf.jpg
+
|room=036
| building             = MPI-CBG
+
|facility_image=logo-lmf.jpg
| room                 = 036
+
|description=Inverted research grade microscope capable many contrasting techniques including Brightfield, Phase Contrast, Darkfield, Differential Interference Contrast (DIC), and Fluorescence
| description         = Inverted research grade microscope capable many contrasting techniques including Brightfield, Phase Contrast, Darkfield, Differential Interference Contrast (DIC), and Fluorescence
+
|applications=-
| applications         = -
+
|image=MPI10.jpg
| microscope           = Zeiss Axiovert 200m
+
|stand=Inverted
| objectives           = Plan Neofluar 5x/0.15 Ph1<br>Plan Neofluar 10x/0.25 Ph1<br>LD Plan Neofluar 20x/0.40 Korr Ph2<br>LD Plan Neofluar 40x/0.60 Korr Ph2<br>Plan Apochromat 100x/1.4 Oil DIC<br>
+
|microscope=Zeiss Axiovert 200m
| illumination         = Halogen<br>HBO
+
|objectives=Plan Neofluar 5x/0.15 Ph1<br>Plan Neofluar 10x/0.25 Ph1<br>LD Plan Neofluar 20x/0.40 Korr Ph2<br>LD Plan Neofluar 40x/0.60 Korr Ph2<br>Plan Apochromat 100x/1.4 Oil DIC<br>
| detection           = Diagnostic Instruments RT Spot
+
|illumination=Halogen<br>HBO
| reflectors           = DAPI (X BP 361-396, D BP 422-639, M BP 434-486)<br>eGFP (X BP 449-488, D BP 495-598, M BP 501-551)<br>TexasRed ( X BP 540-580, D LP 588 , M BP 595-667)<br>Cy5 (X BP 604-649, D LP 664, M LP 661)<br>DIC (BF, Ph1, Ph2, Ph3, DIC II, and DIC III)<br>
+
|detection=Diagnostic Instruments RT Spot
| features             = -
+
|reflectors=DAPI (X BP 361-396, D BP 422-639, M BP 434-486)<br>eGFP (X BP 449-488, D BP 495-598, M BP 501-551)<br>TexasRed ( X BP 540-580, D LP 588 , M BP 595-667)<br>Cy5 (X BP 604-649, D LP 664, M LP 661)<br>DIC (BF, Ph1, Ph2, Ph3, DIC II, and DIC III)<br>
| incubation           = mobile stage incubator
+
|features=-
| link1               = -
+
|incubation=stage incubator (T) + objective heater
| link2               = -
+
|link1=-
| inv                 = 402166
+
|link2=-
 +
|inv=402166
 +
|obj1=-
 +
|obj2=-
 +
|obj3=-
 +
|obj4=-
 +
|obj5=-
 +
|obj6=-
 +
|obj7=-
 +
|obj8=-
 
}}
 
}}

Revision as of 17:12, 1 September 2009

Suitable for -.
MPI10.jpg


Directions

[[image:|150px|text-bottom|right]]

[[image:|100px]] MPI-CBG LMF (MPI-CBG, 036)

Booking

https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py

Details

microscope , Inverted stand, Zeiss Axiovert 200m
objectives
-
-
-
-
-
-
-
-
illumination
detection Diagnostic Instruments RT Spot
reflectors DAPI (X BP 361-396, D BP 422-639, M BP 434-486)
eGFP (X BP 449-488, D BP 495-598, M BP 501-551)
TexasRed ( X BP 540-580, D LP 588 , M BP 595-667)
Cy5 (X BP 604-649, D LP 664, M LP 661)
DIC (BF, Ph1, Ph2, Ph3, DIC II, and DIC III)
features -
software
incubation stage incubator (T) + objective heater
links
  • [ manual]
  • [- laser power values]
  • [- beam path]
  • [ advanced system check]
inv.nr. 402166



Personal tools