WF Olympus upright, BIOTEC

From BioDIP
(Difference between revisions)
Jump to: navigation, search
Line 14: Line 14:
 
|microscope=manual XY stage, motorized Z-stage, fluorescence, transmitted light with manual DIC, color and b/w acquisition
 
|microscope=manual XY stage, motorized Z-stage, fluorescence, transmitted light with manual DIC, color and b/w acquisition
 
|obj1=Olympus UPlanSApo 60x 1.35 Oil
 
|obj1=Olympus UPlanSApo 60x 1.35 Oil
|obj2=-
 
 
|obj3=Olympus UPlanApo 10x 0.4
 
|obj3=Olympus UPlanApo 10x 0.4
|obj4=-
 
|obj5=-
 
|obj6=-
 
|obj7=-
 
|obj8=-
 
 
|ill1=Transmitted Light (Halogen)
 
|ill1=Transmitted Light (Halogen)
 
|ill2=Fluorescence (HBO)
 
|ill2=Fluorescence (HBO)
|ill3=-
 
|ill4=-
 
|ill5=-
 
|ill6=-
 
|ill7=-
 
|ill8=-
 
 
|detection=CCD Leica DFC 500 (1360*1024 up to 4080*3072, 6,45*6,45µm pixel)
 
|detection=CCD Leica DFC 500 (1360*1024 up to 4080*3072, 6,45*6,45µm pixel)
 
|reflectors=DAPI : EX 365/10 ; BS 400 ; EM LP 420<br>FITC : EX 480/20 ; BS 495 ; EM 535/40<br>Cy3 : EX 545/25 ; BS 565 ; EM 605/70<br>TRITC : EX 540/20 ; BS 570 ; EM 590 LP<br>DICT<br>CFP : EX 436/20 ; BS 455 ; EM BP 480/40
 
|reflectors=DAPI : EX 365/10 ; BS 400 ; EM LP 420<br>FITC : EX 480/20 ; BS 495 ; EM 535/40<br>Cy3 : EX 545/25 ; BS 565 ; EM 605/70<br>TRITC : EX 540/20 ; BS 570 ; EM 590 LP<br>DICT<br>CFP : EX 436/20 ; BS 455 ; EM BP 480/40

Revision as of 17:36, 16 September 2009

Suitable for -.
Bioz12.jpg


Directions

[[image:|150px|text-bottom|right]]

[[image:|100px]] Imaging@Biotec"Imaging@Biotec" is not in the list of possible values (DZNE - Imaging Platform, EM- and Histo-Facility CRTD / BIOTEC, Image Processing@BIOTEC, Imaging@BIOTEC/CRTD, MPI-CBG LMF, MPI-CBG LMF - Quantitative Image Analysis Unit, MPI-CBG TDS, MTZ Imaging, MPI-CBG EM, BioDIP) for this property. ("Biotec" is not in the list of possible values (BIOTEC, CRTD, DZNE, MTZ, MPI-CBG) for this property., 229)

Booking

https://techpool.biotec.tu-dresden.de/schedule/schedule.php?scheduleid=sc142df4c59eef5c

Details

microscope , Upright stand, manual XY stage, motorized Z-stage, fluorescence, transmitted light with manual DIC, color and b/w acquisition
objectives
Olympus UPlanSApo 60x 1.35 Oil
Olympus UPlanApo 10x 0.4
illumination
Transmitted Light (Halogen)
Fluorescence (HBO)
detection CCD Leica DFC 500 (1360*1024 up to 4080*3072, 6,45*6,45µm pixel)
reflectors DAPI : EX 365/10 ; BS 400 ; EM LP 420
FITC : EX 480/20 ; BS 495 ; EM 535/40
Cy3 : EX 545/25 ; BS 565 ; EM 605/70
TRITC : EX 540/20 ; BS 570 ; EM 590 LP
DICT
CFP : EX 436/20 ; BS 455 ; EM BP 480/40
features timelapse imaging, z-stack, Brightfield, Fluorescence
software
incubation -
links
  • [ manual]
  • [- laser power values]
  • [- beam path]
  • [ advanced system check]
inv.nr. 0