WF Olympus upright, BIOTEC

From BioDIP
(Difference between revisions)
Jump to: navigation, search
Line 23: Line 23:
 
|ill1=Transmitted Light (Halogen)
 
|ill1=Transmitted Light (Halogen)
 
|ill2=Fluorescence (HBO)
 
|ill2=Fluorescence (HBO)
|detection=CCD Leica DFC 500 (1360*1024 up to 4080*3072, 6,45*6,45µm pixel)
+
|detection=Coolsnap fx (1300x1030 pixel; 6,7x6,7μm; 12bit@20MHz)
 +
Spot Insight QE Color (2048x2048 pixel; 7,4x7,4μm;
 +
14bit@20MHz)
 
|reflectors=DAPI : EX 365/10 ; BS 400 ; EM LP 420<br>FITC : EX 480/20 ; BS 495 ; EM 535/40<br>Cy3 : EX 545/25 ; BS 565 ; EM 605/70<br>TRITC : EX 540/20 ; BS 570 ; EM 590 LP<br>DICT<br>CFP : EX 436/20 ; BS 455 ; EM BP 480/40
 
|reflectors=DAPI : EX 365/10 ; BS 400 ; EM LP 420<br>FITC : EX 480/20 ; BS 495 ; EM 535/40<br>Cy3 : EX 545/25 ; BS 565 ; EM 605/70<br>TRITC : EX 540/20 ; BS 570 ; EM 590 LP<br>DICT<br>CFP : EX 436/20 ; BS 455 ; EM BP 480/40
 
|features=timelapse imaging, z-stack, Brightfield, Fluorescence
 
|features=timelapse imaging, z-stack, Brightfield, Fluorescence

Revision as of 11:35, 30 August 2011

Suitable for -.
Bioz12.jpg


Directions

Imaging@Biotec.jpg Imaging@Biotec"Imaging@Biotec" is not in the list of possible values (DZNE - Imaging Platform, EM- and Histo-Facility CRTD / BIOTEC, Image Processing@BIOTEC, Imaging@BIOTEC/CRTD, MPI-CBG LMF, MPI-CBG LMF - Quantitative Image Analysis Unit, MPI-CBG TDS, MTZ Imaging, MPI-CBG EM, BioDIP) for this property. ("Biotec" is not in the list of possible values (BIOTEC, CRTD, DZNE, MTZ, MPI-CBG) for this property., 229)

Booking

https://techpool.biotec.tu-dresden.de/schedule/schedule.php?scheduleid=sc142df4c59eef5c

Details

microscope Olympus - IX81, Upright stand, manual XY stage, motorized Z-stage, fluorescence, transmitted light with manual DIC, color and b/w acquisition
objectives
Olympus UPlanSApo 60x 1.35 Oil
Olympus UPlanSApo 4x 0.16
Olympus UPlanApo 10x 0.4
Olympus UPlanFluor 20X 0.5
Olympus UPlanSApo 40X 0.9
Olympus PlanApo 100x 1.4 Oil
illumination
Transmitted Light (Halogen)
Fluorescence (HBO)
detection Coolsnap fx (1300x1030 pixel; 6,7x6,7μm; 12bit@20MHz)

Spot Insight QE Color (2048x2048 pixel; 7,4x7,4μm; 14bit@20MHz)

reflectors DAPI : EX 365/10 ; BS 400 ; EM LP 420
FITC : EX 480/20 ; BS 495 ; EM 535/40
Cy3 : EX 545/25 ; BS 565 ; EM 605/70
TRITC : EX 540/20 ; BS 570 ; EM 590 LP
DICT
CFP : EX 436/20 ; BS 455 ; EM BP 480/40
features timelapse imaging, z-stack, Brightfield, Fluorescence
software -
incubation Not available
links
  • [ manual]
  • [- laser power values]
  • [- beam path]
  • [ advanced system check]
inv.nr. 0



Personal tools