Zeiss ApoTome - DZNE W1

From BioDIP
(Difference between revisions)
Jump to: navigation, search
Line 11: Line 11:
 
|applications=-
 
|applications=-
 
|image=ApoTome1 3rd floor, upr., CRTD.jpg
 
|image=ApoTome1 3rd floor, upr., CRTD.jpg
|stand-name=Zeiss - Axio Imager
+
|stand-name=Zeiss - Axio Imager.M2
 
|stand=Upright
 
|stand=Upright
|microscope=motorized XY stage, motorized z-stage, fluorescence, transmitted light with DIC, b/w epifluorescence acquisition, Optical Sectioning (Apotome), color acquisition for stained histological samples
+
|microscope=manual XY stage, motorized z-drive, fluorescence, transmitted light with DIC, Ph, Darkfield b/w epifluorescence acquisition, Optical Sectioning (ApoTome2)
|obj1=Zeiss Plan-Apochromat 10x 0.45
+
|obj1=Zeiss EC Plan Neofluar 2.5x 0.075
|obj2=Zeiss Plan-Apochromat 20x 0.8
+
|obj2=Zeiss Plan-Apochromat 10x 0.45
|obj3=Zeiss Plan-Apochromat 40x 0,95 korr.
+
|obj3=Zeiss Plan-Apochromat 20x 0.8
 
|obj4=Zeiss Plan-Apochromat 40x 0,95 korr.
 
|obj4=Zeiss Plan-Apochromat 40x 0,95 korr.
|obj5=Zeiss EC Plan Neofluar 2.5x 0.075
+
|obj5=Zeiss EC Plan-Neofluar 100x 1.3 Oil
|obj6=Zeiss Achroplan 40x 0.8 W
+
|obj7=Zeiss EC Plan-Neofluar 40x 1.3 Oil
+
 
|ill1=Fluorescence (Metal Halide, HXP, 120W)
 
|ill1=Fluorescence (Metal Halide, HXP, 120W)
 
|ill2=Transmitted Light (Halogen)
 
|ill2=Transmitted Light (Halogen)
|detection=Axiocam MRm (1388*1040, 6,45*6,45µm) - b/w<br>
+
|detection=Axiocam MRm rev.3 (1388*1040, 6,45*6,45µm)
Axiocam MRc (1388*1040 pixel, 6,45*6,45µm) - color
+
 
|reflectors=FS 49: EX BP G365; BS 395; EM  BP 445/50 (Dapi)<br>
 
|reflectors=FS 49: EX BP G365; BS 395; EM  BP 445/50 (Dapi)<br>
 
FS HC-FITC: EX BP 482/35 (HE); BS 505 (HE); EM BP 536/40 (HE); (GFP)<br>
 
FS HC-FITC: EX BP 482/35 (HE); BS 505 (HE); EM BP 536/40 (HE); (GFP)<br>
FS 43HE: EX BP 550/25 (HE); BS 570 (HE); EM 605/70 (HE); (Cy3)<br>
 
 
FS Cy5 HC: EX BP 640/30 ; BS 660 ; EM 690/50; (Cy5)<br>
 
FS Cy5 HC: EX BP 640/30 ; BS 660 ; EM 690/50; (Cy5)<br>
FS 24: EX BP 485/20 - BP 578/14; BS 500 - LP 600; EM 527/25 - LP 610; (GFP-RFP)<br>
+
 
 
FS Analysator for DIC and Transmission
 
FS Analysator for DIC and Transmission
|features=sequential imaging, Brightfield and Fluorescence overlay, timelapse, z-stack, optical sectioning, mosaix scan
+
|features=sequential imaging, Brightfield and Fluorescence overlay, timelapse, z-stack, optical sectioning
|software=Axiovision
+
|software=AxioVision Rel.4.8.2
 
|incubation=Not available
 
|incubation=Not available
 
|inv=0
 
|inv=0
 
}}
 
}}

Revision as of 15:19, 12 March 2012

Suitable for -.
ApoTome1 3rd floor, upr., CRTD.jpg


Directions

[[image:|100px]] DZNE - Imaging Platform (DZNE, 2.08)

Booking

https://techpool.biotec.tu-dresden.de/schedule/schedule.php?scheduleid=sc14ffd3aa3e44c3

Details

microscope Zeiss - Axio Imager.M2, Upright stand, manual XY stage, motorized z-drive, fluorescence, transmitted light with DIC, Ph, Darkfield b/w epifluorescence acquisition, Optical Sectioning (ApoTome2)
objectives
Zeiss EC Plan Neofluar 2.5x 0.075
Zeiss Plan-Apochromat 10x 0.45
Zeiss Plan-Apochromat 20x 0.8
Zeiss Plan-Apochromat 40x 0,95 korr.
Zeiss EC Plan-Neofluar 100x 1.3 Oil
illumination
Fluorescence (Metal Halide, HXP, 120W)
Transmitted Light (Halogen)
detection Axiocam MRm rev.3 (1388*1040, 6,45*6,45µm)
reflectors FS 49: EX BP G365; BS 395; EM BP 445/50 (Dapi)

FS HC-FITC: EX BP 482/35 (HE); BS 505 (HE); EM BP 536/40 (HE); (GFP)
FS Cy5 HC: EX BP 640/30 ; BS 660 ; EM 690/50; (Cy5)

FS Analysator for DIC and Transmission

features sequential imaging, Brightfield and Fluorescence overlay, timelapse, z-stack, optical sectioning
software AxioVision Rel.4.8.2
incubation Not available
links
  • [ manual]
  • [ laser power values]
  • [ beam path]
  • [ advanced system check]
inv.nr. 0