| detection            = point scanner, 4 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, spectral sliders and emission filters for detection range selection, pinhole for each detector
 
| detection            = point scanner, 4 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, spectral sliders and emission filters for detection range selection, pinhole for each detector
 
| reflectors          = Filter 1. U-MWU2[http://www.olympusamerica.com/seg_section/uis2/seg_uis2_mr_umwu2.asp].  BP330-385  BA420  DM400   
 
| reflectors          = Filter 1. U-MWU2[http://www.olympusamerica.com/seg_section/uis2/seg_uis2_mr_umwu2.asp].  BP330-385  BA420  DM400   
Filter 2. U-MWB2 [http://www.olympusamerica.com/seg_section/uis2/seg_uis2_mr_umwb2.asp]. BP460-490  BA520IF(High performance interference filter)  DM500
+
Filter 2. U-MWB2 [http://www.olympusamerica.com/seg_section/uis2/seg_uis2_mr_umwb2.asp]. BP460-490  BA520IF(High performance interference filter)  DM500<br>
 
Filter 3. U-MWG2 [http://www.olympusamerica.com/seg_section/uis2/seg_uis2_mr_umwg2.asp]. BP510-550  BA590  DM570
 
Filter 3. U-MWG2 [http://www.olympusamerica.com/seg_section/uis2/seg_uis2_mr_umwg2.asp]. BP510-550  BA590  DM570
 
| features            = simultaneous imaging using a 405nm picosecond  Diode laser (PicoQuant), sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, Kalman [[averaging]], summarizing, scan zoom and rotation
 
| features            = simultaneous imaging using a 405nm picosecond  Diode laser (PicoQuant), sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, Kalman [[averaging]], summarizing, scan zoom and rotation

Revision as of 10:48, 28 August 2008

Suitable for ablation experiments.
MPI09.jpg


Directions

[[image:|150px|text-bottom|right]]

[[image:|100px]] MPI-CBG LMF (MPI-CBG, 038A)

Booking

https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py

Details

microscope , inverted stand, inverted stand, motorized XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC
objectives
illumination
detection point scanner, 4 confocal PMTs, T-PMT, dichromatic mirrors for excitation/emission splitting, spectral sliders and emission filters for detection range selection, pinhole for each detector
reflectors [[reflectors::Filter 1. U-MWU2[1]. BP330-385 BA420 DM400

Filter 2. U-MWB2 [2]. BP460-490 BA520IF(High performance interference filter) DM500
Filter 3. U-MWG2 [3]. BP510-550 BA590 DM570]]

features [[features::simultaneous imaging using a 405nm picosecond Diode laser (PicoQuant), sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, Kalman averaging, summarizing, scan zoom and rotation]]