| applications        = multi-channel imaging of fixed sample, sample screening, including CFP/Yfp FRET, image acquisition for deconvolution and DIC imaging
 
| applications        = multi-channel imaging of fixed sample, sample screening, including CFP/Yfp FRET, image acquisition for deconvolution and DIC imaging
 
| microscope          = manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC
 
| microscope          = manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC
| objectives          = -<br>-<br>-<br>-<br>-<br>-
+
| objectives          = Plan Neofluar 5x/0.15 Ph1<br>Plan Neofluar 10/0.30<br>Achroplan 63x/0.80<br>Plan Neofluar 100x/1.30 Oil<br>
 
| illumination        = Halogen<br>HBO
 
| illumination        = Halogen<br>HBO
 
| detection            = SPOT camera
 
| detection            = SPOT camera
| reflectors          = -<br>-<br>-<br>-<br>-<br>-
+
| reflectors          = DAPI (X BP 333-383, D LP 408, M BP 432-484)<br>FITC (X BP 446-494, DLP 513, M BP 516-567)<br>TRITC ( X BP 543-554, D LP 578, M BP 579-637<br>YFP 491-509, D LP 517, M BP 519-546)<br>CFP X BP 426-446, D LP 453,M BP 465-499)<br>Brightfield, Darkfield, Phase Contrast, and DIC<br>FITC/TRITC (X DBP 474-490 & 542-566, D DBP 502-533 & 577-677< M DBP 503-533 & 581-621) 
 
| features            = -
 
| features            = -
| incubation          = -
+
| incubation          = Bachoffer Chamber Bookable for this system
 
| link1                = -
 
| link1                = -
 
| link2                = -
 
| link2                = -
 
| inv                  = 401536
 
| inv                  = 401536
 
}}
 
}}

Revision as of 17:26, 15 September 2008

Suitable for multi-channel imaging of fixed sample, sample screening, including CFP/Yfp FRET, image acquisition for deconvolution and DIC imaging.
MPI07.jpg


Directions

[[image:|150px|text-bottom|right]]

[[image:|100px]] MPI-CBG LMF (MPI-CBG, -)

Booking

https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py

Details

microscope , upright stand, manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC
objectives
illumination
detection SPOT camera
reflectors DAPI (X BP 333-383, D LP 408, M BP 432-484)
FITC (X BP 446-494, DLP 513, M BP 516-567)
TRITC ( X BP 543-554, D LP 578, M BP 579-637
YFP 491-509, D LP 517, M BP 519-546)
CFP X BP 426-446, D LP 453,M BP 465-499)
Brightfield, Darkfield, Phase Contrast, and DIC
FITC/TRITC (X DBP 474-490 & 542-566, D DBP 502-533 & 577-677< M DBP 503-533 & 581-621)
features -
software
incubation Bachoffer Chamber Bookable for this system
links
  • [ manual]
  • [- laser power values]
  • [- beam path]
  • [ advanced system check]
inv.nr. 401536