|stand=Inverted
 
|stand=Inverted
 
|microscope=manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC
 
|microscope=manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC
|objectives=Plan Neofluar 5x/0.15 <br>Plan Neofluar 10/0.30<br>Plan Neofluar 25x/0.8 Ph2<br>Plan Neofluar 40x/0.75 Ph2<br>Achroplan 63x/0.80<br>Plan Neofluar 100x/1.30 Oil<br>
 
|illumination=Halogen<br>HBO
 
|detection=Diagnostic Instruments RT SPOT monochrome camera with 1600x1200 pixels (6.7 um^2)
 
|reflectors=DAPI (X BP 333-383, D LP 408, M BP 432-484)<br>FITC (X BP 446-494, DLP 513, M BP 516-567)<br>TRITC ( X BP 543-554, D LP 578, M BP 579-637<br>YFP 491-509, D LP 517, M BP 519-546)<br>CFP X BP 426-446, D LP 453,M BP 465-499)<br>Brightfield, Darkfield, Phase Contrast, and DIC<br>FITC/TRITC (X DBP 474-490 & 542-566, D DBP 502-533 & 577-677< M DBP 503-533 & 581-621)
 
|features=-
 
|incubation=-
 
|link1=-
 
|link2=-
 
|inv=401536
 
 
|obj1=Zeiss EC Plan-Neofluar 5x 0.16
 
|obj1=Zeiss EC Plan-Neofluar 5x 0.16
 
|obj2=Zeiss EC Plan-Neofluar 10x 0.3
 
|obj2=Zeiss EC Plan-Neofluar 10x 0.3
Line 30: Line 21:
 
|obj7=-
 
|obj7=-
 
|obj8=-
 
|obj8=-
 +
|ill1=Transmitted Light (Halogen)
 +
|ill2=Fluorescence (HBO)
 +
|ill3=-
 +
|ill4=-
 +
|ill5=-
 +
|ill6=-
 +
|ill7=-
 +
|ill8=-
 +
|detection=Diagnostic Instruments RT SPOT monochrome camera with 1600x1200 pixels (6.7 um^2)
 +
|reflectors=DAPI (X BP 333-383, D LP 408, M BP 432-484)<br>FITC (X BP 446-494, DLP 513, M BP 516-567)<br>TRITC ( X BP 543-554, D LP 578, M BP 579-637<br>YFP 491-509, D LP 517, M BP 519-546)<br>CFP X BP 426-446, D LP 453,M BP 465-499)<br>Brightfield, Darkfield, Phase Contrast, and DIC<br>FITC/TRITC (X DBP 474-490 & 542-566, D DBP 502-533 & 577-677< M DBP 503-533 & 581-621)
 +
|features=-
 +
|incubation=-
 +
|link1=-
 +
|link2=-
 +
|inv=401536
 +
|objectives=Plan Neofluar 5x/0.15 <br>Plan Neofluar 10/0.30<br>Plan Neofluar 25x/0.8 Ph2<br>Plan Neofluar 40x/0.75 Ph2<br>Achroplan 63x/0.80<br>Plan Neofluar 100x/1.30 Oil<br>
 +
|illumination=Halogen<br>HBO
 
}}
 
}}

Revision as of 10:30, 14 September 2009

Suitable for multi-channel imaging of fixed sample, sample screening, including CFP/Yfp FRET, image acquisition for deconvolution and DIC imaging.
MPI07.jpg


Directions

[[image:|150px|text-bottom|right]]

[[image:|100px]] MPI-CBG LMF (MPI-CBG, 036)

Booking

https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py

Details

microscope , Inverted stand, manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC
objectives
Zeiss EC Plan-Neofluar 5x 0.16
Zeiss EC Plan-Neofluar 10x 0.3
Zeiss LCI Plan-Neofluar 25x 0.8 Imm Corr
Zeiss EC Plan-Neofluar 40x 0.75
Zeiss N-Achroplan 63x 0.85
Zeiss EC Plan-Neofluar 100x 1.3 Oil
-
-
illumination
Transmitted Light (Halogen)
Fluorescence (HBO)
-
-
-
-
-
-
detection Diagnostic Instruments RT SPOT monochrome camera with 1600x1200 pixels (6.7 um^2)
reflectors DAPI (X BP 333-383, D LP 408, M BP 432-484)
FITC (X BP 446-494, DLP 513, M BP 516-567)
TRITC ( X BP 543-554, D LP 578, M BP 579-637
YFP 491-509, D LP 517, M BP 519-546)
CFP X BP 426-446, D LP 453,M BP 465-499)
Brightfield, Darkfield, Phase Contrast, and DIC
FITC/TRITC (X DBP 474-490 & 542-566, D DBP 502-533 & 577-677< M DBP 503-533 & 581-621)
features -
software
incubation -
links
  • [ manual]
  • [- laser power values]
  • [- beam path]
  • [ advanced system check]