CO1 - Olympus Fluoview 1000
From BioDIP
(Difference between revisions)
m (moved Olympus Fluoview 1000 to CO1 - Olympus Fluoview 1000: to match booking database) |
|||
Line 11: | Line 11: | ||
|applications=ablation experiments | |applications=ablation experiments | ||
|image=MPI09.jpg | |image=MPI09.jpg | ||
+ | |stand-name=Olympus - IX81 | ||
|stand=Inverted | |stand=Inverted | ||
|microscope=motorized XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | |microscope=motorized XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC |
Revision as of 17:50, 30 March 2010
Directions
[[image:|150px|text-bottom|right]]
Booking
https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py
Details
microscope | Olympus - IX81, Inverted stand, motorized XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | ||
objectives | |||
illumination | |||
detection | [[detection::point scanner, 4 confocal PMTs, two independent spectral detection channels, each one configured with a diffraction grating and variable slit for high-resolution wavelength separation and high-speed bandwidth selection, two filter based detection channels, T-PMT, dichromatic mirrors for excitation/emission splitting, one pinhole]] | ||
reflectors | [[reflectors::Filter Cube 1. U-MWU2. BP330-385 BA420 DM400
Filter Cube 2. U-MWB2. BP460-490 BA520IF (High performance interference filter) DM500 | ||
features | Two independent and fully synchronized laser scanners for simultaneous laser stimulation and observation, laser stimulation can be performed using the imaging laser or a 405nm picosecond Diode laser (PicoQuant), sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, Kalman averaging, summarizing, scan zoom and rotation; advanced use of motorized stage due to MATL-software, which allows independent multi-point acquisition and tiling + some simple stitching"Two independent and fully synchronized laser scanners for simultaneous laser stimulation and observation, laser stimulation can be performed using the imaging laser or a 405nm picosecond Diode laser (PicoQuant), sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, Kalman averaging, summarizing, scan zoom and rotation; advanced use of motorized stage due to MATL-software, which allows independent multi-point acquisition and tiling + some simple stitching" cannot be used as a page name in this wiki. | ||
software | FV10-ASW 1.7 | ||
incubation | Stage incubator (T+CO2) | ||
links |
| ||
inv.nr. | - |