MZ1 - Zeiss 2photon upright

From BioDIP
(Difference between revisions)
Jump to: navigation, search
Line 27: Line 27:
 
|ill8=Laser Multiphoton Chameleon 700-1064 nm
 
|ill8=Laser Multiphoton Chameleon 700-1064 nm
 
|detection=2 confocal PMTs, QUASAR detector with 34 channels, T-PMT, 2 non-descanned detectors (NDD) <br>
 
|detection=2 confocal PMTs, QUASAR detector with 34 channels, T-PMT, 2 non-descanned detectors (NDD) <br>
dichromatic mirrors for excitation/emission splitting, spectral prism sliders for emission detection range selection, common pinhole changeable for each detector setting <br>
+
dichromatic mirrors for excitation/emission splitting, spectral prism sliders for emission detection range selection, common pinhole changeable for each detector setting; <br>
[http://docs.google.com/present/view?id=dchc5whx_96c978c866 NDDs]
+
[http://docs.google.com/present/view?id=dchc5whx_96c978c866 NDD-dichromatic mirrors and emission filters]
 
|reflectors=-
 
|reflectors=-
 
|features=simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation, tile scan, multi position scan, spectral scan
 
|features=simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation, tile scan, multi position scan, spectral scan

Revision as of 15:57, 1 April 2010

  • Multiphoton Laser Scanning Microscope with a tunable pulsed infra-red laser for multiphoton excitation.
  • Single photon point scanning confocal system with three PMTs (one spectral) and transmitted light detector. Motorized stage for multi-point acquisition"Zeiss LSM 710 NLO
  • Multiphoton Laser Scanning Microscope with a tunable pulsed infra-red laser for multiphoton excitation.
  • Single photon point scanning confocal system with three PMTs (one spectral) and transmitted light detector. Motorized stage for multi-point acquisition" cannot be used as a page name in this wiki.

Suitable for imaging of thick specimens fast bleaching samples. Spectral imaging, routine dye combinations, tile scan, multi position scan..
MZ1-Zeiss 2photon upr.png


Directions

[[image:|150px|text-bottom|right]]

[[image:|100px]] MPI-CBG LMF (MPI-CBG, 038C)

Booking

https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py

Details

microscope Zeiss - Axio Examiner, Upright stand, motorized XY stage, motorized Z-drive,
objectives
Zeiss EC Plan-Neofluar 10x 0.3
Zeiss C-Apochromat 40x 1.2 W
Zeiss W Plan-Apochromat 40x/1.0
illumination
Fluorescence (Metal Halide, PRIOR, 200W)
Transmitted Light (Halogen)
Laser Diode 405 nm
Laser Argon Multiline 458, 477, 488, 514 nm
Laser DPSS 561 nm
Laser HeNe 594 nm
Laser HeNe 633 nm
Laser Multiphoton Chameleon 700-1064 nm
detection [[detection::2 confocal PMTs, QUASAR detector with 34 channels, T-PMT, 2 non-descanned detectors (NDD)

dichromatic mirrors for excitation/emission splitting, spectral prism sliders for emission detection range selection, common pinhole changeable for each detector setting;
NDD-dichromatic mirrors and emission filters]]

reflectors -
features simultaneous imaging, sequential imaging, line scan, point scan, Z stacks, time-series, advanced time-series, averaging, summarizing, scan zoom and rotation, tile scan, multi position scan, spectral scan
software Zen 2009
incubation Not available
links
  • [ manual]
  • [ laser power values]
  • [ beam path]
  • [ advanced system check]
inv.nr. AIM System 2501000451