W3 - Zeiss CCD Upright

From BioDIP
(Difference between revisions)
Jump to: navigation, search
Line 6: Line 6:
 
|facility=MPI-CBG LMF
 
|facility=MPI-CBG LMF
 
|building=MPI-CBG
 
|building=MPI-CBG
|room=036
+
|room=211
|facility_image=logo-lmf.jpg
+
 
|description=It is an upright, motorized microscope with medium sensitivity CCD camera, fitted with uniblitz shutters.
 
|description=It is an upright, motorized microscope with medium sensitivity CCD camera, fitted with uniblitz shutters.
 
|applications=multi-channel imaging of fixed sample, sample screening, including CFP/Yfp FRET, image acquisition for deconvolution and DIC imaging
 
|applications=multi-channel imaging of fixed sample, sample screening, including CFP/Yfp FRET, image acquisition for deconvolution and DIC imaging
Line 14: Line 13:
 
|stand=Upright
 
|stand=Upright
 
|microscope=manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC
 
|microscope=manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC
|obj1=Zeiss EC Plan-Neofluar 5x 0.16
+
|obj1=Zeiss Plan-Neofluar 100x 1.3 Oil
|obj2=Zeiss EC Plan-Neofluar 10x 0.3
+
|obj3=Zeiss LCI Plan-Neofluar 25x 0.8 Imm Corr
+
|obj4=Zeiss EC Plan-Neofluar 40x 0.75
+
|obj5=Zeiss N-Achroplan 63x 0.85
+
|obj6=Zeiss EC Plan-Neofluar 100x 1.3 Oil
+
 
|ill1=Transmitted Light (Halogen)
 
|ill1=Transmitted Light (Halogen)
 
|ill2=Fluorescence (HBO)
 
|ill2=Fluorescence (HBO)
Line 30: Line 24:
 
|link2=-
 
|link2=-
 
|inv=401536
 
|inv=401536
 +
|facility_image=logo-lmf.jpg
 
|objectives=Plan Neofluar 5x/0.15 <br>Plan Neofluar 10/0.30<br>Plan Neofluar 25x/0.8 Ph2<br>Plan Neofluar 40x/0.75 Ph2<br>Achroplan 63x/0.80<br>Plan Neofluar 100x/1.30 Oil<br>
 
|objectives=Plan Neofluar 5x/0.15 <br>Plan Neofluar 10/0.30<br>Plan Neofluar 25x/0.8 Ph2<br>Plan Neofluar 40x/0.75 Ph2<br>Achroplan 63x/0.80<br>Plan Neofluar 100x/1.30 Oil<br>
 
|illumination=Halogen<br>HBO
 
|illumination=Halogen<br>HBO
 
}}
 
}}

Revision as of 12:33, 19 August 2011

Suitable for multi-channel imaging of fixed sample, sample screening, including CFP/Yfp FRET, image acquisition for deconvolution and DIC imaging.
MPI07.jpg


Directions

[[image:|150px|text-bottom|right]]

[[image:|100px]] MPI-CBG LMF (MPI-CBG, 211)

Booking

https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py

Details

microscope Zeiss - Axioplan 2, Upright stand, manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC
objectives
Zeiss Plan-Neofluar 100x 1.3 Oil
illumination
Transmitted Light (Halogen)
Fluorescence (HBO)
detection Diagnostic Instruments RT SPOT monochrome camera with 1600x1200 pixels (6.7 um^2)
reflectors DAPI (X BP 333-383, D LP 408, M BP 432-484)
FITC (X BP 446-494, DLP 513, M BP 516-567)
TRITC ( X BP 543-554, D LP 578, M BP 579-637
YFP 491-509, D LP 517, M BP 519-546)
CFP X BP 426-446, D LP 453,M BP 465-499)
Brightfield, Darkfield, Phase Contrast, and DIC
FITC/TRITC (X DBP 474-490 & 542-566, D DBP 502-533 & 577-677< M DBP 503-533 & 581-621)
features -
software -
incubation Not available
links
  • [ manual]
  • [- laser power values]
  • [- beam path]
  • [ advanced system check]
inv.nr. 401536