|facility=MPI-CBG LMF | |facility=MPI-CBG LMF | ||
|building=MPI-CBG | |building=MPI-CBG | ||
− | |room= | + | |room=211 |
− | + | ||
|description=It is an upright, motorized microscope with medium sensitivity CCD camera, fitted with uniblitz shutters. | |description=It is an upright, motorized microscope with medium sensitivity CCD camera, fitted with uniblitz shutters. | ||
|applications=multi-channel imaging of fixed sample, sample screening, including CFP/Yfp FRET, image acquisition for deconvolution and DIC imaging | |applications=multi-channel imaging of fixed sample, sample screening, including CFP/Yfp FRET, image acquisition for deconvolution and DIC imaging | ||
Line 14: | Line 13: | ||
|stand=Upright | |stand=Upright | ||
|microscope=manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | |microscope=manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | ||
− | |obj1=Zeiss | + | |obj1=Zeiss Plan-Neofluar 100x 1.3 Oil |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
|ill1=Transmitted Light (Halogen) | |ill1=Transmitted Light (Halogen) | ||
|ill2=Fluorescence (HBO) | |ill2=Fluorescence (HBO) | ||
Line 30: | Line 24: | ||
|link2=- | |link2=- | ||
|inv=401536 | |inv=401536 | ||
+ | |facility_image=logo-lmf.jpg | ||
|objectives=Plan Neofluar 5x/0.15 <br>Plan Neofluar 10/0.30<br>Plan Neofluar 25x/0.8 Ph2<br>Plan Neofluar 40x/0.75 Ph2<br>Achroplan 63x/0.80<br>Plan Neofluar 100x/1.30 Oil<br> | |objectives=Plan Neofluar 5x/0.15 <br>Plan Neofluar 10/0.30<br>Plan Neofluar 25x/0.8 Ph2<br>Plan Neofluar 40x/0.75 Ph2<br>Achroplan 63x/0.80<br>Plan Neofluar 100x/1.30 Oil<br> | ||
|illumination=Halogen<br>HBO | |illumination=Halogen<br>HBO | ||
}} | }} |
Revision as of 12:33, 19 August 2011
Directions
[[image:|150px|text-bottom|right]]
Booking
https://python-srv1.mpi-cbg.de/lmf-ipf/cgi-bin/index.py
Details
microscope | Zeiss - Axioplan 2, Upright stand, manual XY stage, motorized Z-drive, fluorescence, transmitted light with manual DIC | ||
objectives | |||
illumination | |||
detection | Diagnostic Instruments RT SPOT monochrome camera with 1600x1200 pixels (6.7 um^2) | ||
reflectors | DAPI (X BP 333-383, D LP 408, M BP 432-484) FITC (X BP 446-494, DLP 513, M BP 516-567) TRITC ( X BP 543-554, D LP 578, M BP 579-637 YFP 491-509, D LP 517, M BP 519-546) CFP X BP 426-446, D LP 453,M BP 465-499) Brightfield, Darkfield, Phase Contrast, and DIC FITC/TRITC (X DBP 474-490 & 542-566, D DBP 502-533 & 577-677< M DBP 503-533 & 581-621) | ||
features | - | ||
software | - | ||
incubation | Not available | ||
links |
| ||
inv.nr. | 401536 |